Material review · Self-adhered SBS underlayment
MetalSeal HT Review: The Water Barrier Beneath Your Metal Roof
A metal roof needs more than well-made panels. MetalSeal HT is one option for the water barrier below them. This review explains its Florida approvals, installation choices and pressure ratings so you can ask better questions about your estimate.

Westlake Royal MetalSeal HT
Self-adhered SBS underlayment
What belongs beneath your new roof?
Compare the underlayment and complete roof assembly for your home.
The short answer
MetalSeal HT is a high-temperature, self-adhered option beneath an approved metal roof. Its fabric surface, fastener sealing and 180-day temporary exposure allowance are useful features. The installation still matters: the Florida evaluation rates specific MetalSeal HT assemblies. Those pressures are separate from the capacity of the panels, clips and complete roof.

Beyond the name on the roll
What Westlake Royal MetalSeal HT brings to the roof
Designed with metal roofing in mind
Westlake lists heat resistance up to 260°F for MetalSeal HT. Proper laps, flashing and a compatible finished covering remain essential. That temperature is not an installation temperature or a fire classification.
Preparation changes the approved number
The Florida report lists distinct plywood constructions with no primer listed, ASTM D41 primer, or Karnak #89 primer. Their allowable pressures differ. An estimate should name the preparation instead of saying only “peel-and-stick.”
No universal pressure for the roll
The report’s overall maximum, −255 psf, belongs to structural-concrete assembly C2. It does not apply to plywood. The examples below keep each pressure tied to its specified wood deck and attachment.
Two useful specifications
Thickness and wind resistance at a glance
Material thickness
64 mils
Nominal thickness · 0.064 inch · about 1.63 mm
The Florida evaluation lists 64 mils. Westlake’s brochure identifies this as nominal thickness; older 60-mil listings should not replace that value.
Assembly wind resistance
−142.5 to −210 psf
Listed allowable design pressures
These values come from Florida D1, D2 and D3 assemblies with different primer requirements. The reviewed NOA gives MetalSeal HT no numeric pressure.
See the assemblies, installation and sources →Pressure ratings apply to the specific deck and installation listed in each approval. They are not wind speeds or a rating for the entire roof. Thickness alone does not determine wind resistance.
Does it fit your roof and your location?
Broward and Miami-Dade are in Florida’s High-Velocity Hurricane Zone (HVHZ). Palm Beach and Martin County are outside that zone. The applicable approval, roof covering and installation must agree.
Broward & Miami-Dade · HVHZ
NOA E(1) names MetalSeal HT with approved metal roofing, wood shakes/shingles and asphalt shingles over its specified base-sheet construction.
That assembly excludes tile and supplies no numerical underlayment pressure.
Florida · inside and outside HVHZ
FL14317-R19 explicitly names MetalSeal HT in its numerical assemblies and permits the listed metal, tile and other steep-slope coverings.
Use a complete applicable approval path. Do not borrow the NOA’s TileSeal-only pressure rows.
Review panels, fastening, underlayment, flashing and coastal exposure together. Plan a complete metal roof →
What the approval actually measures
How much uplift can the approved assembly resist?
For MetalSeal HT, the chart uses the Florida evaluation because it explicitly names this product in each numbered assembly. Negative psf measures allowable suction for that construction. It does not describe the metal-panel attachment or a hurricane wind-speed guarantee.
Read these as assembly ratings, not wind speeds
These are allowable design pressures in pounds per square foot (psf), not miles per hour or a hurricane-category rating. A larger magnitude represents more allowable uplift for that listed assembly. It does not measure the entire roof or the tile foam alone. Your roof’s required pressures depend on its design and location.
Florida approval · direct-to-plywood assemblies
FL14317-R19 includes HVHZ and non-HVHZ use. The same specified plywood and cap fastening appear in these three rows; the required primer changes.
Select a bar to see the deck, installation and source.
−142.5 psf
Deck: Minimum 15/32 in, 32/16 span-rated, 4-ply Exposure 1 plywood, DOC PS-1. Structural deck design is separate.
Installation: No base or primer listed. Selvage backnails 12 in o.c.: minimum No.12-gauge (0.105 in) corrosion-resistant ring-shank roofing nails, 3/8 in heads, 32-gauge x 1-5/8 in tin caps. Immediately steel-roll, minimum 75 lb; laps minimum 3 in side/6 in end.
Limits: Only this plywood construction; the deck’s structural design is evaluated separately.
FL14317-R19 / PRI ER 2458E01-FBC2023, p. 2 — read the complete approval−202.5 psf
Deck: Minimum 15/32 in, 32/16 span-rated, 4-ply Exposure 1 plywood, DOC PS-1. Structural deck design is separate.
Installation: No base. Primer: ASTM D41 primer required. Selvage backnails 12 in o.c.: minimum No.12-gauge (0.105 in) corrosion-resistant ring-shank roofing nails, 3/8 in heads, 32-gauge x 1-5/8 in tin caps. Immediately steel-roll, minimum 75 lb; laps minimum 3 in side/6 in end.
Limits: Requires ASTM D41 primer and all listed attachment/application conditions.
FL14317-R19 / PRI ER 2458E01-FBC2023, p. 2 — read the complete approval−210 psf

Deck: Minimum 15/32 in, 32/16 span-rated, 4-ply Exposure 1 plywood, DOC PS-1. Structural deck design is separate.
Installation: No base. Primer: Karnak #89 Sta-Tak Primer required. Selvage backnails 12 in o.c.: minimum No.12-gauge (0.105 in) corrosion-resistant ring-shank roofing nails, 3/8 in heads, 32-gauge x 1-5/8 in tin caps. Immediately steel-roll, minimum 75 lb; laps minimum 3 in side/6 in end.
Limits: Requires the named Karnak primer; do not substitute any primer and retain this rating.
FL14317-R19 / PRI ER 2458E01-FBC2023, p. 3 — read the complete approvalBars show the magnitude of the listed negative design pressure. The minus sign denotes uplift. Different decks and installation methods are separate assemblies.
Compare another underlayment’s own approved uses and assembly requirements. Read the TU PLUS review →
Material testing · Source checked October 27, 2026
Beyond wind pressure: how does the sheet perform?
Tear resistance, tensile strength and vapor permeance describe different jobs. Here is what the reviewed documents actually report for Westlake Royal MetalSeal HT.

Tear resistance
Number not publishedHow well the sheet resists a tear spreading. Test methods can pull or tear the material in very different ways.
ASTM D1970 compliance only
No measured value in reviewed documents
Tear resistanceNot published in the reviewed sources
The approval confirms standards compliance, but the reviewed documents do not provide a measured tear result.
Florida Product ApprovalFL14317-R19 / PRI ER2458E01-FBC2023 · p1
Tensile strength
Number not publishedHow much pulling force the sheet carries before reaching its reported maximum load. This is a material test, not a roof uplift rating.
ASTM D1970 compliance only
No measured value in reviewed documents
Tensile / maximum loadNot published in the reviewed sources
The approval confirms standards compliance, but the reviewed documents do not provide a measured pulling-strength result.
Florida Product ApprovalFL14317-R19 / PRI ER2458E01-FBC2023 · p1
Vapor permeance
Number not publishedHow readily water vapor passes through the sheet. A lower perm value means less vapor passes through; it does not automatically mean a better roof.
Not stated for a numerical permeance measurement
No measured value in reviewed documents
Vapor permeanceNot published in the reviewed sources
The approval describes a vapor barrier, but the reviewed documents do not provide a measured perm value.
Florida Product ApprovalFL14317-R19 installation/ventilation provisions · p5
What the NOA and Florida approval establish
NOA 25-0407.04 and FL14317-R19 establish ASTM D1970/TAS103 compliance and assembly-specific wind resistance, without publishing numeric tear, tensile or permeance values. PRI ER1378E04 separately confirms physical-properties testing without results. No current official numerical fallback was found.
- Miami-Dade NOA 25-0407.04, product descriptions/evidence · p2
- FL14317-R19 / PRI ER2458E01-FBC2023 · p1
- PRI ER1378E04, physical properties · p6
The approval determines permitted uses and installation. Where it does not publish these laboratory values, the cards identify the original manufacturer sheet as the source. A manufacturer value is not relabeled as an NOA test result.
How to compare these numbers
MD means the direction along the roll; CD or XMD means across it. Match the method, units, direction, conditioning and whether a figure is a minimum, maximum or typical result. A published minimum is a floor—not proof of a product’s highest strength.
Use the exact approved assembly for wind-pressure comparisons. Vapor permeance is a roof-design consideration, and M&M’s installation experience adds context to the laboratory figures.
Compare underlayment options for your roof →The details worth discussing before installation
Why do the NOA and Florida report differ?
The combined NOA’s numerical E(2)–F(1) rows specify TileSeal HT. MetalSeal HT appears in E(1) without a number. The separate Florida evaluation names both products in its pressure rows. This review uses that explicit listing.
What needs to happen before the metal goes on?
The Florida report requires a clean, dry, sound substrate, minimum 2:12 slope and application at 40°F or above unless the manufacturer is consulted. The panels may need a steeper slope. Sealed laps, primed metal flashing and immediate rolling belong in the plan.
How much uncovered time is allowed?
The 180-day allowance is temporary; inspect membrane condition before covering. A Citadel Pro base layer, if selected, has a separate 30-day exposure limit. Westlake advertises a 30-year limited warranty. Request its terms alongside workmanship coverage.
Westlake product page; exposure confirmed by PRI evaluation p. 5
What should be named in your estimate?
A useful proposal identifies the materials and the installation that will be inspected—not simply “underlayment included.” Ask for:
- MetalSeal HT approval and selected assembly.
- Plywood condition, primer and any base sheet.
- Membrane fastening, rolling, laps and flashing.
- Metal-panel approval and separate attachment design.
Choose the layers together
M&M Roofing can help you compare underlayment options with the roof covering, deck condition and attachment your project needs.
Plan my roof replacement →Homeowner questions about Westlake Royal MetalSeal HT
Can I use a TileSeal HT NOA number for MetalSeal HT?
They share a combined NOA, but each assembly specifies its products. MetalSeal HT appears in E(1); the numerical rows name TileSeal HT. Use the Florida evaluation for the MetalSeal HT numbers shown here.
Does MetalSeal HT make my metal roof Class A?
Not by itself. The NOA does not evaluate fire classification. Ask for the applicable finished-roof documentation; high-temperature underlayment does not automatically make every metal assembly Class A.
Does a primer automatically give the highest pressure?
No. The listed primer works with a specified deck, backnailing and rolling method. A different preparation does not inherit that pressure. The permit documents should identify the chosen assembly.
Your roof, your approved assembly
Get a roof estimate with the details included
Tell M&M Roofing about your home and the roof covering you are considering.
Start with the approvals
The NOAs and Florida Product Approval reports are the primary evidence for the installation limits and ratings above. Manufacturer literature provides the additional product and warranty information. These documents describe approved conditions; they are not endorsements.
- Primary approval: Miami-Dade County NOA 25-0407.04 · approved November 27, 2025 · expires August 2, 2028
Assembly pages 4–12; limitations page 13. Current record reports File Approved. - Primary approval: Florida approval FL14317-R19 · approved July 18, 2025
2023 FBC; approved inside and outside HVHZ; current record is not archived. - Evaluation report: PRI ER 2458E01-FBC2023 · July 8, 2025
Pressure tables pages 2–4; installation and compatibility pages 5–6. - Manufacturer: Westlake Royal MetalSeal HT product information
Product description and limited warranty. The page has template errors in its FAQ; those claims are not used here. - Manufacturer brochure: MetalSeal HT brochure · April 2023, currently linked by Westlake
Original product imagery and 260°F heat statement p. 3. Approval conditions govern installation.
Technical summaries help compare proposals. The full current documents and the project’s approved plans control installation.