Material review · Self-adhered SBS underlayment

MetalSeal HT Review: The Water Barrier Beneath Your Metal Roof

A metal roof needs more than well-made panels. MetalSeal HT is one option for the water barrier below them. This review explains its Florida approvals, installation choices and pressure ratings so you can ask better questions about your estimate.

Original Westlake Royal Roofing Components logo

Westlake Royal MetalSeal HT

Self-adhered SBS underlayment

What belongs beneath your new roof?

Compare the underlayment and complete roof assembly for your home.

Add project details (optional)

No obligation. We use your details to respond to this request.

Prefer to speak now? (754) 714-8445

The short answer

MetalSeal HT is a high-temperature, self-adhered option beneath an approved metal roof. Its fabric surface, fastener sealing and 180-day temporary exposure allowance are useful features. The installation still matters: the Florida evaluation rates specific MetalSeal HT assemblies. Those pressures are separate from the capacity of the panels, clips and complete roof.

Westlake Royal MetalSeal HT manufacturer product roll photograph
Official Westlake product photograph; not an M&M project installation. Image source

Beyond the name on the roll

What Westlake Royal MetalSeal HT brings to the roof

Designed with metal roofing in mind

Westlake lists heat resistance up to 260°F for MetalSeal HT. Proper laps, flashing and a compatible finished covering remain essential. That temperature is not an installation temperature or a fire classification.

Preparation changes the approved number

The Florida report lists distinct plywood constructions with no primer listed, ASTM D41 primer, or Karnak #89 primer. Their allowable pressures differ. An estimate should name the preparation instead of saying only “peel-and-stick.”

No universal pressure for the roll

The report’s overall maximum, −255 psf, belongs to structural-concrete assembly C2. It does not apply to plywood. The examples below keep each pressure tied to its specified wood deck and attachment.

Two useful specifications

Thickness and wind resistance at a glance

Material thickness

64 mils

Nominal thickness · 0.064 inch · about 1.63 mm

The Florida evaluation lists 64 mils. Westlake’s brochure identifies this as nominal thickness; older 60-mil listings should not replace that value.

Assembly wind resistance

−142.5 to −210 psf

Listed allowable design pressures

These values come from Florida D1, D2 and D3 assemblies with different primer requirements. The reviewed NOA gives MetalSeal HT no numeric pressure.

See the assemblies, installation and sources →

Pressure ratings apply to the specific deck and installation listed in each approval. They are not wind speeds or a rating for the entire roof. Thickness alone does not determine wind resistance.

Does it fit your roof and your location?

Broward and Miami-Dade are in Florida’s High-Velocity Hurricane Zone (HVHZ). Palm Beach and Martin County are outside that zone. The applicable approval, roof covering and installation must agree.

Broward & Miami-Dade · HVHZ

NOA E(1) names MetalSeal HT with approved metal roofing, wood shakes/shingles and asphalt shingles over its specified base-sheet construction.

That assembly excludes tile and supplies no numerical underlayment pressure.

Read the approved uses and limitations →

Florida · inside and outside HVHZ

FL14317-R19 explicitly names MetalSeal HT in its numerical assemblies and permits the listed metal, tile and other steep-slope coverings.

Use a complete applicable approval path. Do not borrow the NOA’s TileSeal-only pressure rows.

Read the approved uses and limitations →

Review panels, fastening, underlayment, flashing and coastal exposure together. Plan a complete metal roof →

What the approval actually measures

How much uplift can the approved assembly resist?

For MetalSeal HT, the chart uses the Florida evaluation because it explicitly names this product in each numbered assembly. Negative psf measures allowable suction for that construction. It does not describe the metal-panel attachment or a hurricane wind-speed guarantee.

Read these as assembly ratings, not wind speeds

These are allowable design pressures in pounds per square foot (psf), not miles per hour or a hurricane-category rating. A larger magnitude represents more allowable uplift for that listed assembly. It does not measure the entire roof or the tile foam alone. Your roof’s required pressures depend on its design and location.

Florida approval · direct-to-plywood assemblies

FL14317-R19 includes HVHZ and non-HVHZ use. The same specified plywood and cap fastening appear in these three rows; the required primer changes.

Select a bar to see the deck, installation and source.

D1 · no primer listed−142.5 psf

Deck: Minimum 15/32 in, 32/16 span-rated, 4-ply Exposure 1 plywood, DOC PS-1. Structural deck design is separate.

Installation: No base or primer listed. Selvage backnails 12 in o.c.: minimum No.12-gauge (0.105 in) corrosion-resistant ring-shank roofing nails, 3/8 in heads, 32-gauge x 1-5/8 in tin caps. Immediately steel-roll, minimum 75 lb; laps minimum 3 in side/6 in end.

Limits: Only this plywood construction; the deck’s structural design is evaluated separately.

FL14317-R19 / PRI ER 2458E01-FBC2023, p. 2 — read the complete approval
D2 · ASTM D41 primer−202.5 psf

Deck: Minimum 15/32 in, 32/16 span-rated, 4-ply Exposure 1 plywood, DOC PS-1. Structural deck design is separate.

Installation: No base. Primer: ASTM D41 primer required. Selvage backnails 12 in o.c.: minimum No.12-gauge (0.105 in) corrosion-resistant ring-shank roofing nails, 3/8 in heads, 32-gauge x 1-5/8 in tin caps. Immediately steel-roll, minimum 75 lb; laps minimum 3 in side/6 in end.

Limits: Requires ASTM D41 primer and all listed attachment/application conditions.

FL14317-R19 / PRI ER 2458E01-FBC2023, p. 2 — read the complete approval
D3 · Karnak #89 primer−210 psf

Deck: Minimum 15/32 in, 32/16 span-rated, 4-ply Exposure 1 plywood, DOC PS-1. Structural deck design is separate.

Installation: No base. Primer: Karnak #89 Sta-Tak Primer required. Selvage backnails 12 in o.c.: minimum No.12-gauge (0.105 in) corrosion-resistant ring-shank roofing nails, 3/8 in heads, 32-gauge x 1-5/8 in tin caps. Immediately steel-roll, minimum 75 lb; laps minimum 3 in side/6 in end.

Limits: Requires the named Karnak primer; do not substitute any primer and retain this rating.

FL14317-R19 / PRI ER 2458E01-FBC2023, p. 3 — read the complete approval

Bars show the magnitude of the listed negative design pressure. The minus sign denotes uplift. Different decks and installation methods are separate assemblies.

Compare another underlayment’s own approved uses and assembly requirements. Read the TU PLUS review →

Material testing · Source checked October 27, 2026

Beyond wind pressure: how does the sheet perform?

Tear resistance, tensile strength and vapor permeance describe different jobs. Here is what the reviewed documents actually report for Westlake Royal MetalSeal HT.

Original Westlake Royal Roofing Components logo

Tear resistance

Number not published

How well the sheet resists a tear spreading. Test methods can pull or tear the material in very different ways.

ASTM D1970 compliance only

No measured value in reviewed documents

Tear resistanceNot published in the reviewed sources

No numeric bar — missing or unresolved data is not zero.

The approval confirms standards compliance, but the reviewed documents do not provide a measured tear result.

Florida Product ApprovalFL14317-R19 / PRI ER2458E01-FBC2023 · p1

Tensile strength

Number not published

How much pulling force the sheet carries before reaching its reported maximum load. This is a material test, not a roof uplift rating.

ASTM D1970 compliance only

No measured value in reviewed documents

Tensile / maximum loadNot published in the reviewed sources

No numeric bar — missing or unresolved data is not zero.

The approval confirms standards compliance, but the reviewed documents do not provide a measured pulling-strength result.

Florida Product ApprovalFL14317-R19 / PRI ER2458E01-FBC2023 · p1

Vapor permeance

Number not published

How readily water vapor passes through the sheet. A lower perm value means less vapor passes through; it does not automatically mean a better roof.

Not stated for a numerical permeance measurement

No measured value in reviewed documents

Vapor permeanceNot published in the reviewed sources

No numeric bar — missing or unresolved data is not zero.

The approval describes a vapor barrier, but the reviewed documents do not provide a measured perm value.

Florida Product ApprovalFL14317-R19 installation/ventilation provisions · p5

What the NOA and Florida approval establish

NOA 25-0407.04 and FL14317-R19 establish ASTM D1970/TAS103 compliance and assembly-specific wind resistance, without publishing numeric tear, tensile or permeance values. PRI ER1378E04 separately confirms physical-properties testing without results. No current official numerical fallback was found.

The approval determines permitted uses and installation. Where it does not publish these laboratory values, the cards identify the original manufacturer sheet as the source. A manufacturer value is not relabeled as an NOA test result.

How to compare these numbers

MD means the direction along the roll; CD or XMD means across it. Match the method, units, direction, conditioning and whether a figure is a minimum, maximum or typical result. A published minimum is a floor—not proof of a product’s highest strength.

Use the exact approved assembly for wind-pressure comparisons. Vapor permeance is a roof-design consideration, and M&M’s installation experience adds context to the laboratory figures.

Compare underlayment options for your roof →

The details worth discussing before installation

Why do the NOA and Florida report differ?

The combined NOA’s numerical E(2)–F(1) rows specify TileSeal HT. MetalSeal HT appears in E(1) without a number. The separate Florida evaluation names both products in its pressure rows. This review uses that explicit listing.

NOA 25-0407.04, pp. 4–12

What needs to happen before the metal goes on?

The Florida report requires a clean, dry, sound substrate, minimum 2:12 slope and application at 40°F or above unless the manufacturer is consulted. The panels may need a steeper slope. Sealed laps, primed metal flashing and immediate rolling belong in the plan.

PRI evaluation, p. 5

How much uncovered time is allowed?

The 180-day allowance is temporary; inspect membrane condition before covering. A Citadel Pro base layer, if selected, has a separate 30-day exposure limit. Westlake advertises a 30-year limited warranty. Request its terms alongside workmanship coverage.

Westlake product page; exposure confirmed by PRI evaluation p. 5

What should be named in your estimate?

A useful proposal identifies the materials and the installation that will be inspected—not simply “underlayment included.” Ask for:

  1. MetalSeal HT approval and selected assembly.
  2. Plywood condition, primer and any base sheet.
  3. Membrane fastening, rolling, laps and flashing.
  4. Metal-panel approval and separate attachment design.

Choose the layers together

M&M Roofing can help you compare underlayment options with the roof covering, deck condition and attachment your project needs.

Plan my roof replacement →

Homeowner questions about Westlake Royal MetalSeal HT

Can I use a TileSeal HT NOA number for MetalSeal HT?

They share a combined NOA, but each assembly specifies its products. MetalSeal HT appears in E(1); the numerical rows name TileSeal HT. Use the Florida evaluation for the MetalSeal HT numbers shown here.

Does MetalSeal HT make my metal roof Class A?

Not by itself. The NOA does not evaluate fire classification. Ask for the applicable finished-roof documentation; high-temperature underlayment does not automatically make every metal assembly Class A.

Does a primer automatically give the highest pressure?

No. The listed primer works with a specified deck, backnailing and rolling method. A different preparation does not inherit that pressure. The permit documents should identify the chosen assembly.

Your roof, your approved assembly

Get a roof estimate with the details included

Tell M&M Roofing about your home and the roof covering you are considering.

Add project details (optional)

No obligation. We use your details to respond to this request.

Prefer to speak now? (754) 714-8445

Start with the approvals

The NOAs and Florida Product Approval reports are the primary evidence for the installation limits and ratings above. Manufacturer literature provides the additional product and warranty information. These documents describe approved conditions; they are not endorsements.

  1. Primary approval: Miami-Dade County NOA 25-0407.04 · approved November 27, 2025 · expires August 2, 2028
    Assembly pages 4–12; limitations page 13. Current record reports File Approved.
  2. Primary approval: Florida approval FL14317-R19 · approved July 18, 2025
    2023 FBC; approved inside and outside HVHZ; current record is not archived.
  3. Evaluation report: PRI ER 2458E01-FBC2023 · July 8, 2025
    Pressure tables pages 2–4; installation and compatibility pages 5–6.
  4. Manufacturer: Westlake Royal MetalSeal HT product information
    Product description and limited warranty. The page has template errors in its FAQ; those claims are not used here.
  5. Manufacturer brochure: MetalSeal HT brochure · April 2023, currently linked by Westlake
    Original product imagery and 260°F heat statement p. 3. Approval conditions govern installation.

Technical summaries help compare proposals. The full current documents and the project’s approved plans control installation.