Polyset RTA-1 · Tile adhesive review
RTA-1: what this one-part tile foam means for your roof
Review APOC Polyset RTA-1 with its Miami-Dade NOA, Polystick TU MAX compatibility and tile-by-tile graphs against AH-160, TILE BOND and StormBond 2.
By M&M Roofing and Construction Corp · Florida Certified Roofing Contractor CCC1332459 · Published · Updated
Get a free tile roof estimate
Compare the tile, waterproofing and attachment in a complete estimate.
The short answer
RTA-1 is still listed by APOC, and it can be an option for holding roof tiles in place when the approved system fits your home. What matters most is whether your exact tile, underlayment and attachment detail work together. Ask your roofer to name those materials in writing, show how the attachment meets your roof’s wind requirements, and explain the waterproofing and warranty included in the price.

What should you care about as the homeowner?
The foam is mostly hidden once your roof is finished, but its job matters: it helps hold the tiles in place. A useful estimate explains how that attachment works with the tile you selected and the waterproofing underneath it.
Will the tiles stay attached?
Have the roofer identify the tile, foam and approved attachment detail, then check it against the wind requirements for your roof—including edges and corners.
What keeps the house dry?
The underlayment and flashing beneath and around the tile are essential to keeping water out. A foam choice cannot make up for damaged or poorly installed waterproofing.
What happens if a repair is needed?
Ask who handles loose tiles or leaks, what the workmanship warranty covers and whether matching replacement tiles will be available.
Still choosing the look? Browse our tile samples and tile roofing guide alongside the attachment options.
RTA-1 has its own product and approval
APOC 705 Polyset RTA-1 is a one-component polyurethane roof tile adhesive in the ICP family. APOC lists a 23 lb cylinder and a 24 oz straw-foam can. Those formats can be useful for different job sizes, but local availability should be confirmed with the supplier.
AH-160 is a separate two-component product. With RTA-1, there is no A/B mixing step; that difference alone does not establish better attachment, a lower installed price or interchangeability. The current RTA-1 NOA identifies the HFO formulation.
Miami-Dade component approval
NOA 25-1219.03 (opens in a new tab)
- Approved
- January 29, 2026
- Stated expiration
- January 3, 2027
- Status checked October 23
- File Approved
This document renews and revises NOA 22-0614.08. The tile’s own NOA supplies its attachment values. Recheck the current approval when the project is specified, especially as the stated expiration approaches.
Official APOC product listing (opens in a new tab) · How to check a roofing approval
Eight tile profiles · Four adhesive choices
How does RTA-1 compare on your tile?
Select a tile below to compare RTA-1 with AH-160, TILE BOND and StormBond 2, the two-component DAP product. The numbers measure the listed resistance to a tile lifting and rotating. A higher bar applies to that specific tile and attachment arrangement.
The unit is ft-lbf, an attachment-resistance moment called Mf. These values do not tell you a wind speed or directly measure how strongly a foam sticks to Polystick TU MAX. A “paddy” means a placed amount of foam; “headlap” is where the tiles overlap.
One detail needs to be resolved before using RTA-1 on a project
Some foam amounts and contact areas in the tile approvals differ from the current RTA-1 component approval. That component document also has differences between its table and drawings. The bars below faithfully show the published tile values; ICP and the roof designer need to reconcile the applicable installation details before they are used for your roof.
RTA-1 component NOA · Table 1 and drawings, pages 4–7 (opens in a new tab)
Compare the same tile
How do the attachment choices compare?
Choose a tile to see its published attachment values. A higher number means more listed resistance to that tile lifting and rotating in the named arrangement. Foam amounts and patterns can differ, so these are not equal-dose tests or a universal brand ranking.
Westlake · Flat concrete
Saxony 900 Slate
Tile NOA 24-1008.12 · page 6 · Table 5 (opens in a new tab)
Lake Wales, FL production covered by this tile NOA. The RTA-1 number is a published tile-table result. Its foam amount or contact detail needs reconciliation with the current component approval before project use.
Listed attachment resistance · Mf · ft-lbf
All bars start at zero. The scale stays from zero to 140 foot-pounds when changing tiles.

APOC Polyset RTA-1 · HFO
Two paddies: 12 g underlayment + 10 g headlap
41 ft-lbfSource entry · page 6 · Table 5 (opens in a new tab)
Mass and contact minimums align with the flat HFO drawing; tile row says 1 x 10 inch headlap while component drawing says 1 x 8 inch bead and minimum 10 in2 contact. Component Table 1 versus drawing conflict still needs resolution.

APOC Polyset AH-160 · HFC / HFO1
Single paddy: 45 g
119 ft-lbf
DuPont TILE BOND
Independent · two paddies: 25 g each
65 ft-lbfSource entry · page 6 · Table 5 (opens in a new tab)
The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation.

DAP StormBond 2
Two paddies: 8 g each
109 ft-lbf
View all tile values and sources in a table
| Tile | Adhesive | Mf · ft-lbf | Pattern and source |
|---|---|---|---|
| Westlake Saxony 900 SlateFlat concrete | APOC Polyset RTA-1 · HFO | 41 | Two paddies: 12 g underlayment + 10 g headlap Source · page 6 · Table 5 (opens in a new tab) Mass and contact minimums align with the flat HFO drawing; tile row says 1 x 10 inch headlap while component drawing says 1 x 8 inch bead and minimum 10 in2 contact. Component Table 1 versus drawing conflict still needs resolution. |
| Westlake Saxony 900 SlateFlat concrete | APOC Polyset AH-160 · HFC / HFO1 | 119 | Single paddy: 45 g |
| Westlake Saxony 900 SlateFlat concrete | DuPont TILE BOND | 65 | Independent · two paddies: 25 g each Source · page 6 · Table 5 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. |
| Westlake Saxony 900 SlateFlat concrete | DAP StormBond 2 | 109 | Two paddies: 8 g each |
| Crown Windsor SlateFlat concrete | APOC Polyset RTA-1 · HFO | 38 | Two paddies, 11 g each Source · page 7 · Table 5 (opens in a new tab) Tile row specifies 11 g each; component flat HFO drawing specifies 12 g underlayment and 10 g headlap. Contact is unspecified in tile table. Reconcile quantities and contact before installation. |
| Crown Windsor SlateFlat concrete | APOC Polyset AH-160 · HFC / HFO1 | 119 | Single paddy: 45 g |
| Crown Windsor SlateFlat concrete | DuPont TILE BOND | 65 | Independent · two paddies: 25 g each Source · page 7 · Table 5 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. |
| Crown Windsor SlateFlat concrete | DAP StormBond 2 | 122 | Two paddies: 8 g each |
| Westlake Villa 900Medium-profile concrete | APOC Polyset RTA-1 · HFO | 71 | Two paddies: 12 g underlayment + 10 g headlap Source · page 6 · Table 5 (opens in a new tab) Tile row headlap contact is 8 in2; component medium HFO drawing requires at least 10 in2. Mass matches the drawing, but contact detail needs reconciliation. |
| Westlake Villa 900Medium-profile concrete | APOC Polyset AH-160 · HFC / HFO1 | 87 | Single paddy: 54 g |
| Westlake Villa 900Medium-profile concrete | DuPont TILE BOND | 67 | Independent · two paddies: 25 g each Source · page 6 · Table 5 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. |
| Westlake Villa 900Medium-profile concrete | DAP StormBond 2 | 55 | Two paddies: 8 g each |
| Crown TuscanyMedium-profile concrete | APOC Polyset RTA-1 · HFO | 44.6 | Two paddies: 12 g underlayment + 10 g headlap Source · page 6 · Table 6 (opens in a new tab) Tile row headlap contact is 8 in2; component medium HFO drawing requires at least 10 in2. Mass matches the drawing, but contact detail needs reconciliation. |
| Crown TuscanyMedium-profile concrete | APOC Polyset AH-160 · HFC / HFO1 | 87 | Single paddy: 54 g |
| Crown TuscanyMedium-profile concrete | DuPont TILE BOND | 67 | Independent · two paddies: 25 g each Source · page 6 · Table 6 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. |
| Crown TuscanyMedium-profile concrete | DAP StormBond 2 | 108 | Two paddies: 8 g each |
| Westlake Barcelona 900High-profile concrete | APOC Polyset RTA-1 · HFO | 44 | Two paddies: 12 g underlayment + 12 g headlap Source · page 6 · Table 5 (opens in a new tab) Tile row headlap contact is 10 in2; component high HFO drawing requires at least 18 in2. Mass matches the drawing, but contact detail needs reconciliation. |
| Westlake Barcelona 900High-profile concrete | APOC Polyset AH-160 · HFC / HFO1 | 67 | Single paddy: 63 g |
| Westlake Barcelona 900High-profile concrete | DuPont TILE BOND | 58 | Independent · two paddies: 12.5 g each Source · page 6 · Table 5 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. |
| Westlake Barcelona 900High-profile concrete | DAP StormBond 2 | 66 | Two paddies: 8 g each |
| Crown SanibelHigh-profile concrete | APOC Polyset RTA-1 · HFO | 53.5 | Two paddies: 22 g underlayment + 11 g headlap Source · page 5 · Table 5 (opens in a new tab) Tile row has 22 g underlayment and 11 g headlap; component high HFO drawing specifies 12 g each. Headlap mass is below that drawing; tile contact is unspecified. Needs reconciliation. |
| Crown SanibelHigh-profile concrete | APOC Polyset AH-160 · HFC / HFO1 | 67 | Single paddy: 63 g |
| Crown SanibelHigh-profile concrete | DuPont TILE BOND | 58 | Independent · two paddies: 12.5 g each Source · page 5 · Table 5 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. |
| Crown SanibelHigh-profile concrete | DAP StormBond 2 | 101 | Two paddies: 8 g each |
| Verea Spanish S · Grade 1One-piece clay | APOC Polyset RTA-1 · HFO | Unavailable | No entry in the reviewed tile approval Source · page 5 · Tables 6–7 (opens in a new tab) No approval or performance value for this pairing is inferred from another tile. |
| Verea Spanish S · Grade 1One-piece clay | APOC Polyset AH-160 · HFC / HFO1 | 63 | Single paddy: 34.6 g |
| Verea Spanish S · Grade 1One-piece clay | DuPont TILE BOND | 54 | Independent · two paddies: 27.5 g each Source · page 5 · Table 6 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. |
| Verea Spanish S · Grade 1One-piece clay | DAP StormBond 2 | 83 | Two paddies: 9.7 g each |
| Verea True Barrel · Grade 1Two-piece clay | APOC Polyset RTA-1 · HFO | Unavailable | No entry in the reviewed tile approval Source · page 5 · Table 6 (opens in a new tab) No approval or performance value for this pairing is inferred from another tile. |
| Verea True Barrel · Grade 1Two-piece clay | ICP Polyset AH-160 · legacy HFC | 118.31 | 34.6 g per pan; 17.3 g on each side of cap Source · page 5 · Table 6 (opens in a new tab) Legacy Polyset AH-160 entry; not an HFO1 or HFO2 result. Table 6, footnote 3. |
| Verea True Barrel · Grade 1Two-piece clay | DuPont TILE BOND | 89.8 | 12.5 g per pan; 12.5 g on each side of cap Source · page 5 · Table 6 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. Table 6, footnote 4. |
| Verea True Barrel · Grade 1Two-piece clay | DAP StormBond 2 | Unavailable | No entry in the reviewed tile approval Source · page 5 · Table 6 (opens in a new tab) No approval or performance value for this pairing is inferred from another tile. |
How we selected the comparison entries
Each tile keeps the same four products in the same order on a fixed 0–140 scale. We show the RTA-1 HFO two-paddy row, a listed AH-160 HFC/HFO1 single-paddy row, the TILE BOND independent row and the StormBond 2 two-paddy row where available. These use different foam amounts and contact patterns; they are selected published arrangements, not equal-dose tests or the maximum result for every brand.
Verea True Barrel is a separate cap-and-pan system. Its AH-160 result retains the legacy HFC identity and its TILE BOND result uses the cap-and-pan detail. RTA-1 is absent from both reviewed Verea tile approvals; StormBond 2 is absent from the reviewed True Barrel table. Missing entries stay unplotted.
AH-160 HFO2 and other attachment patterns are not silently substituted. One-component StormBond is a separate product covered in our StormBond review.
The question to take to your roofer is: “Does this exact attachment detail meet the requirements for my house?” A number for another tile, another formula or another foam pattern cannot answer that.
The waterproofing beneath the tile
Can RTA-1 go over Polystick TU MAX?
Polyglass’s compatibility table lists APOC Polyset RTA-1 with Polystick TU MAX. That is a useful starting point when reviewing the proposed materials.
The table does not separately name an HFO version. Confirm the supplied formulation and the whole assembly: the wood deck, underlayment attachment, tile, foam placement and roof design all matter. Compatibility alone is not a strength rating for the complete roof.
For the waterproofing side of your estimate, read our Polystick TU MAX review. Ask how flashing, roof penetrations and any damaged decking will be handled along with the tile attachment.
Workmanship matters after the product is chosen
A trained installer and a specific plan
The RTA-1 NOA requires a factory-trained, ICP-qualified applicator. Ask who is installing the foam and which approved tile and placement detail the crew will follow.
Tile placement has a time limit
The component approval requires placing the tile within four minutes after dispensing. This is a placement window, not a full-cure time or a time when the roof is safe to walk on.
Foam does not automatically eliminate fasteners
Approved roof details can still require screws, clips or other mechanical attachment at particular locations or slopes. Have the estimate identify where foam and other attachment methods will be used.
A repair starts with finding the cause
A loose or broken tile may call for more than additional adhesive. The roofer should check the surrounding tile, the underlayment and the cause of movement or leakage before choosing a repair.
RTA-1 qualification and installation requirements (opens in a new tab)
Our roof repair team can assess the visible problem and the work needed beneath it.
Compare the complete price and written warranty
A can or cylinder price does not tell you what the finished roof will cost. Compare the same scope: tear-off, wood repairs, underlayment, flashing, tile and trim, approved attachment, permits, cleanup and workmanship coverage. The selected foam pattern and roof conditions affect the work involved.
Ask for two separate sets of terms
Get the product warranty for the exact package supplied and the contractor’s workmanship warranty. The linked RTA-1 straw-foam technical sheet provides a limited one-year material-defect warranty from purchase. Its remedies are replacement or a prorated purchase-price refund at APOC’s discretion, with exclusions including labor and installation. That is not a promise to pay for replacing the roof or repairing leak damage.
Straw-foam technical sheet · limited warranty, page 2 (opens in a new tab)
Use our Broward tile roof cost guide for broader planning, then get an estimate tied to your actual home.
Frequently asked questions
Is Polyset RTA-1 still sold?
APOC currently lists APOC 705 Polyset RTA-1 on its official website in a 23 lb cylinder and a 24 oz straw-foam can. That confirms it is in the manufacturer’s listed range, but it does not confirm stock at a particular South Florida supplier.
Is RTA-1 the same foam as AH-160?
No. RTA-1 is a one-component polyurethane tile adhesive. AH-160 is a separate two-component system. They have different approvals and application details, so the name APOC or ICP alone is not specific enough for an estimate.
Is RTA-1 strong enough for my roof?
That depends on your tile and the attachment requirements for your house. The graphs show published values for specific tile-and-foam arrangements. The roofer and designer must check the selected detail against the roof’s wind demand and resolve the document differences identified in this review.
Can RTA-1 be used with Polystick TU MAX?
Polyglass NOA 25-0121.12 lists APOC Polyset RTA-1 as compatible with Polystick TU MAX. The table does not separately label an HFO version. Confirm the exact supplied formulation, tile approval and complete underlayment assembly before specifying the combination.
Can I use the concrete-tile result for my Verea clay tile?
No. The reviewed Verea Spanish S and True Barrel approvals do not list RTA-1 attachment values. The graphs show those gaps explicitly. A value for a Crown or Westlake concrete tile does not establish approval for a Verea clay tile.
Will adding RTA-1 fix a loose tile or a roof leak?
A repair first needs to establish why the tile moved and whether the tile, underlayment or surrounding roof is damaged. Foam holds tiles; underlayment and flashing provide waterproofing beneath them. Adding foam alone is not a complete diagnosis or repair plan.
Does the four-minute rule mean the foam is cured?
No. The RTA-1 component NOA requires tile placement within four minutes after dispensing. That is an installation window, not permission to walk on the roof or a full-cure time. The installer must follow the current instructions for the exact product and conditions.
Does the foam warranty cover the whole roof?
Do not assume it does. The linked RTA-1 straw-foam technical sheet has a limited one-year material-defect warranty from purchase, with replacement or prorated purchase-price remedies at APOC’s discretion and exclusions including labor and installation. Obtain the current terms for the package supplied and a separate written workmanship warranty.
Sources checked October 23, 2026
- APOC 705 Polyset RTA-1 · manufacturer product page (opens in a new tab)Product identity, currently listed packaging and original manufacturer product image. Listing checked October 23, 2026; local stock not established.
- RTA-1 · component NOA 25-1219.03 (opens in a new tab)Approved January 29, 2026; stated expiration January 3, 2027. Installer qualifications, four-minute placement window and component attachment details. Table 1 and HFO drawings contain differences described in this review.
- Miami-Dade current file status · RTA-1 (opens in a new tab)File Approved when checked October 23, 2026. Recheck status and any successor document when specifying a project.
- APOC 705 RTA-1 STRAW FOAM · D23 technical sheet (opens in a new tab)This sheet explicitly covers straw foam. Page 2 provides limited warranty wording. Its cure and coverage figures are not generalized to the cylinder in this review.
- Polyglass underlayments · NOA 25-0121.12 (opens in a new tab)Page 18: Polystick TU MAX compatibility table includes APOC Polyset RTA-1 without a separate HFO designation.
- APOC Polyset AH-160 · component NOA 23-0614.01 (opens in a new tab)Separate two-component adhesive. Concrete and Spanish S chart rows use HFC/HFO1; the True Barrel row retains its legacy HFC identity. HFO2 values are not substituted.
- TILE BOND · component NOA 26-0306.01 (opens in a new tab)Current component requirements. Tile-table product labels, foam quantities and independent attachment details remain visible in the comparison.
- StormBond 2 · component NOA 22-0512.02 (opens in a new tab)Two-component product used in the graphs; its component approval permits tile-specific application details. Separate from one-component StormBond.
- Westlake Saxony 900 Slate · tile NOA 24-1008.12 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- Crown Windsor Slate · tile NOA 25-0127.10 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- Westlake Villa 900 · tile NOA 26-0602.02 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- Crown Tuscany · tile NOA 25-0127.09 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- Westlake Barcelona 900 · tile NOA 24-1008.13 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- Crown Sanibel · tile NOA 24-1008.16 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- Verea Spanish S · Grade 1 · tile NOA 25-0206.03 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- Verea True Barrel · Grade 1 · tile NOA 22-1202.03 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
Product approvals are revised and renewed. Confirm the current document for the exact product, plant and roof system when your permit is prepared. This guide is general information for homeowners, not an engineering or permit determination for a specific roof.
Choose the roof system that fits your home
Talk through tile styles, underlayment, attachment and the work included in your roof estimate.
Call (754) 714-8445