The short answer

StormBond is worth considering as part of an approved tile roof system, but get the exact version in writing. StormBond uses one component; StormBond 2 uses two components mixed during application. They have separate approvals and installation requirements. The right choice is the detail that meets your roof’s needs and can be installed correctly.

DAP manufacturer photograph of a gloved installer applying StormBond 2 foam beside curved red roof tiles.
Original DAP application photograph showing StormBond 2. This is a manufacturer reference, not an M&M Roofing project. The gray underlayment in the photograph has not been identified as Polystick TU MAX.

Start with the whole roof

What should a homeowner care about?

The name on a quote needs to be more specific than “StormBond foam.” DAP sells a one-component StormBond product and a two-component StormBond 2 system. Both are polyurethane roof tile adhesives, but their handling and listed attachment results differ. The number 2 is a product distinction, not a strength grade.

Wind attachment is the useful question

Ask whether the specified system meets the wind demand for your roof’s shape and zones. A high number from another tile or foam pattern does not answer that question.

Installation timing deserves attention

The approved instructions give crews a short window to set tiles into fresh foam. Consistent handling, contact and placement matter because the product name alone cannot show how the work was done.

Keep waterproofing in the conversation

Foam attachment can be part of a good roof, but underlayment and flashing still need their own clear scope. Ask for photos and inspection records of the layers that will be hidden by the tile.

Four questions behind a good tile roof

Will the tile stay attached?

The approval needs to cover your exact tile and attachment pattern. Your roof’s corners, edges and field can have different demands. Ask which approved detail the estimate includes.

Ask your roofer

Can you show me the tile approval and the attachment plan for my roof?

Choosing the tile too? Browse tile colors and profiles and our tile roofing service guide alongside the attachment options.

StormBond and StormBond 2 are different products

The one-component and two-component products should appear as separate choices in an estimate. StormBond 2 needs the specified A/B mix, while the one-component product cures with moisture. Both component approvals require factory-trained, qualified applicators. Ask who will apply the adhesive and which product they are trained to use.

StormBond · one component

NOA 26-0514.07 (opens in a new tab)

Approval date
July 23, 2026
Stated expiration
July 21, 2031

Current approval includes StormBond and its Low GWP entry. It renews 23-0327.12; older technical sheets can still cite that earlier number.

Storm Bond 2 · two components

NOA 22-0512.02 (opens in a new tab)

Approval date
November 23, 2022
Stated expiration
April 13, 2027

Separate two-component approval. Confirm the HFC/HFO formulation, mixing equipment and approved tile detail for the product being supplied.

County status checked October 22, 2026: the component documents above are listed as File Approved. The tile’s own approval supplies attachment-resistance values. Read both together; a component NOA alone is not a design for your roof.

DAP manufacturer photograph of StormBond 2 Low GWP A and B tanks and kits.
DAP’s StormBond 2 manufacturer image shows the two-part product format. Product packaging and formulation must match the approval used for the roof.

Our guide to checking a roofing product approval explains what to look for when comparing proposals.

The layer beneath your tile

Can it be used with Polystick TU MAX?

Yes—Polyglass’s compatibility table lists both DAP Storm Bond and Storm Bond 2 with Polystick TU MAX. The tile, foam detail and underlayment attachment still have to match the approved roof assembly.

Use the exact product name and formulation from the proposal and supplied kit when checking these documents.

Polyglass NOA 25-0121.12 · compatibility table, page 18

Compatibility answers whether materials can be used together under the listed conditions. It does not replace the fastening or adhesion requirements beneath the membrane. Read our Polystick TU MAX review for the waterproofing side of the system.

Eight tile profiles · Four adhesive choices

How does StormBond 2 compare with RTA-1, AH-160 and TILE BOND?

Choose a tile below to compare all four products using that tile’s published approval. The graph covers flat and curved concrete tiles, one-piece clay and the separate Verea True Barrel cap-and-pan system. Each value links to its source page and table.

A “paddy” is a placed amount of foam; “headlap” is where the tiles overlap. The numbers measure resistance to the tile lifting and rotating, called Mf, in ft-lbf. They are not wind speeds or direct tests of the foam’s bond to Polystick TU MAX.

APOC logo

Two different APOC / ICP foams

Polyset RTA-1 · one component

APOC currently lists RTA-1 in cylinder and straw-foam formats. Its HFO component approval is NOA 25-1219.03 (opens in a new tab), with a stated expiration of January 3, 2027. The concrete-tile bars use the RTA-1 HFO rows.

Read the separate RTA-1 review

Polyset AH-160 · two components

AH-160 has its own NOA 23-0614.01 (opens in a new tab), with a stated expiration of May 10, 2027. Its bars use the named HFC/HFO1 tile entries; True Barrel retains its legacy HFC identity. HFO2 is a separate formulation.

Read the AH-160 review

For Polystick TU MAX, the Polyglass compatibility table (opens in a new tab) names RTA-1 and AH-160 HFC. It does not separately establish RTA-1 HFO or AH-160 HFO1/HFO2 compatibility. Confirm the exact supplied product and complete roof assembly.

RTA-1 details need to be reconciled before project use

Some foam amounts and contact areas in the tile approvals differ from the current RTA-1 component approval, which also has differences between its table and drawings. The graph shows the published tile values. ICP and the roof designer need to resolve the applicable details before using them for your roof.

RTA-1 component NOA · Table 1 and drawings, pages 4–7 (opens in a new tab)

Compare the same tile

How do the attachment choices compare?

Choose a tile to see its published attachment values. A higher number means more listed resistance to that tile lifting and rotating in the named arrangement. Foam amounts and patterns can differ, so these are not equal-dose tests or a universal brand ranking.

Westlake · Flat concrete

Saxony 900 Slate

Tile NOA 24-1008.12 · page 6 · Table 5 (opens in a new tab)

Lake Wales, FL production covered by this tile NOA. The RTA-1 number is a published tile-table result. Its foam amount or contact detail needs reconciliation with the current component approval before project use.

Listed attachment resistance · Mf · ft-lbf

All bars start at zero. The scale stays from zero to 140 foot-pounds when changing tiles.

Match the number to the whole detail. These are attachment-resistance moments, not wind-speed ratings or direct foam-to-underlayment bond tests. The tile, adhesive formulation, contact area and placement must match the approved roof design. Printed foam quantities identify the source entries; they are not jobsite dispensing instructions.
View all tile values and sources in a table
Published attachment values for each tile and named adhesive detail. Missing values are unavailable, not zero.
TileAdhesiveMf · ft-lbfPattern and source
Westlake Saxony 900 SlateFlat concreteAPOC Polyset RTA-1 · HFO41

Two paddies: 12 g underlayment + 10 g headlap

Source · page 6 · Table 5 (opens in a new tab)

Mass and contact minimums align with the flat HFO drawing; tile row says 1 x 10 inch headlap while component drawing says 1 x 8 inch bead and minimum 10 in2 contact. Component Table 1 versus drawing conflict still needs resolution.

Westlake Saxony 900 SlateFlat concreteAPOC Polyset AH-160 · HFC / HFO1119

Single paddy: 45 g

Source · page 7 · Table 6 (opens in a new tab)

Westlake Saxony 900 SlateFlat concreteDuPont TILE BOND65

Independent · two paddies: 25 g each

Source · page 6 · Table 5 (opens in a new tab)

The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation.

Westlake Saxony 900 SlateFlat concreteDAP StormBond 2109

Two paddies: 8 g each

Source · page 6 · Table 5 (opens in a new tab)

Crown Windsor SlateFlat concreteAPOC Polyset RTA-1 · HFO38

Two paddies, 11 g each

Source · page 7 · Table 5 (opens in a new tab)

Tile row specifies 11 g each; component flat HFO drawing specifies 12 g underlayment and 10 g headlap. Contact is unspecified in tile table. Reconcile quantities and contact before installation.

Crown Windsor SlateFlat concreteAPOC Polyset AH-160 · HFC / HFO1119

Single paddy: 45 g

Source · page 8 · Table 6 (opens in a new tab)

Crown Windsor SlateFlat concreteDuPont TILE BOND65

Independent · two paddies: 25 g each

Source · page 7 · Table 5 (opens in a new tab)

The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation.

Crown Windsor SlateFlat concreteDAP StormBond 2122

Two paddies: 8 g each

Source · page 7 · Table 5 (opens in a new tab)

Westlake Villa 900Medium-profile concreteAPOC Polyset RTA-1 · HFO71

Two paddies: 12 g underlayment + 10 g headlap

Source · page 6 · Table 5 (opens in a new tab)

Tile row headlap contact is 8 in2; component medium HFO drawing requires at least 10 in2. Mass matches the drawing, but contact detail needs reconciliation.

Westlake Villa 900Medium-profile concreteAPOC Polyset AH-160 · HFC / HFO187

Single paddy: 54 g

Source · page 6 · Table 6 (opens in a new tab)

Westlake Villa 900Medium-profile concreteDuPont TILE BOND67

Independent · two paddies: 25 g each

Source · page 6 · Table 5 (opens in a new tab)

The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation.

Westlake Villa 900Medium-profile concreteDAP StormBond 255

Two paddies: 8 g each

Source · page 6 · Table 5 (opens in a new tab)

Crown TuscanyMedium-profile concreteAPOC Polyset RTA-1 · HFO44.6

Two paddies: 12 g underlayment + 10 g headlap

Source · page 6 · Table 6 (opens in a new tab)

Tile row headlap contact is 8 in2; component medium HFO drawing requires at least 10 in2. Mass matches the drawing, but contact detail needs reconciliation.

Crown TuscanyMedium-profile concreteAPOC Polyset AH-160 · HFC / HFO187

Single paddy: 54 g

Source · page 6 · Table 7 (opens in a new tab)

Crown TuscanyMedium-profile concreteDuPont TILE BOND67

Independent · two paddies: 25 g each

Source · page 6 · Table 6 (opens in a new tab)

The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation.

Crown TuscanyMedium-profile concreteDAP StormBond 2108

Two paddies: 8 g each

Source · page 6 · Table 6 (opens in a new tab)

Westlake Barcelona 900High-profile concreteAPOC Polyset RTA-1 · HFO44

Two paddies: 12 g underlayment + 12 g headlap

Source · page 6 · Table 5 (opens in a new tab)

Tile row headlap contact is 10 in2; component high HFO drawing requires at least 18 in2. Mass matches the drawing, but contact detail needs reconciliation.

Westlake Barcelona 900High-profile concreteAPOC Polyset AH-160 · HFC / HFO167

Single paddy: 63 g

Source · page 7 · Table 6 (opens in a new tab)

Westlake Barcelona 900High-profile concreteDuPont TILE BOND58

Independent · two paddies: 12.5 g each

Source · page 6 · Table 5 (opens in a new tab)

The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation.

Westlake Barcelona 900High-profile concreteDAP StormBond 266

Two paddies: 8 g each

Source · page 6 · Table 5 (opens in a new tab)

Crown SanibelHigh-profile concreteAPOC Polyset RTA-1 · HFO53.5

Two paddies: 22 g underlayment + 11 g headlap

Source · page 5 · Table 5 (opens in a new tab)

Tile row has 22 g underlayment and 11 g headlap; component high HFO drawing specifies 12 g each. Headlap mass is below that drawing; tile contact is unspecified. Needs reconciliation.

Crown SanibelHigh-profile concreteAPOC Polyset AH-160 · HFC / HFO167

Single paddy: 63 g

Source · page 6 · Table 6 (opens in a new tab)

Crown SanibelHigh-profile concreteDuPont TILE BOND58

Independent · two paddies: 12.5 g each

Source · page 5 · Table 5 (opens in a new tab)

The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation.

Crown SanibelHigh-profile concreteDAP StormBond 2101

Two paddies: 8 g each

Source · page 5 · Table 5 (opens in a new tab)

Verea Spanish S · Grade 1One-piece clayAPOC Polyset RTA-1 · HFOUnavailable

No entry in the reviewed tile approval

Source · page 5 · Tables 6–7 (opens in a new tab)

No approval or performance value for this pairing is inferred from another tile.

Verea Spanish S · Grade 1One-piece clayAPOC Polyset AH-160 · HFC / HFO163

Single paddy: 34.6 g

Source · page 5 · Table 7 (opens in a new tab)

Verea Spanish S · Grade 1One-piece clayDuPont TILE BOND54

Independent · two paddies: 27.5 g each

Source · page 5 · Table 6 (opens in a new tab)

The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation.

Verea Spanish S · Grade 1One-piece clayDAP StormBond 283

Two paddies: 9.7 g each

Source · page 5 · Table 6 (opens in a new tab)

Verea True Barrel · Grade 1Two-piece clayAPOC Polyset RTA-1 · HFOUnavailable

No entry in the reviewed tile approval

Source · page 5 · Table 6 (opens in a new tab)

No approval or performance value for this pairing is inferred from another tile.

Verea True Barrel · Grade 1Two-piece clayICP Polyset AH-160 · legacy HFC118.31

34.6 g per pan; 17.3 g on each side of cap

Source · page 5 · Table 6 (opens in a new tab)

Legacy Polyset AH-160 entry; not an HFO1 or HFO2 result. Table 6, footnote 3.

Verea True Barrel · Grade 1Two-piece clayDuPont TILE BOND89.8

12.5 g per pan; 12.5 g on each side of cap

Source · page 5 · Table 6 (opens in a new tab)

The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. Table 6, footnote 4.

Verea True Barrel · Grade 1Two-piece clayDAP StormBond 2Unavailable

No entry in the reviewed tile approval

Source · page 5 · Table 6 (opens in a new tab)

No approval or performance value for this pairing is inferred from another tile.

Which attachment patterns are shown?

The main graph uses RTA-1 HFO two-paddy entries, AH-160 HFC/HFO1 single-paddy entries, TILE BOND independent entries and StormBond 2 two-paddy entries where listed. Foam amounts and patterns differ; these are selected published arrangements, not equal-dose tests or each brand’s maximum result. All tile choices use the same 0–140 scale.

True Barrel uses its own cap-and-pan arrangements and the legacy AH-160 HFC entry. RTA-1 has no listed value in the two reviewed Verea clay approvals; StormBond 2 has no listed value in the reviewed True Barrel table. Those gaps are left unplotted, not assigned a strength of zero.

What does this mean for your estimate?

For Saxony 900 Slate, the selected StormBond 2 two-paddy detail lists 109 ft-lbf and RTA-1 lists 41. For Villa 900, those selected entries list 55 and 71. Different foam amounts and contact details are involved. The useful question is which exact tile-and-attachment arrangement meets your home’s requirements.

What about one-component StormBond?

The main comparison uses StormBond 2, the two-component product. One-component StormBond has separate values and application requirements. Several concrete-tile entries differ from the minimums in its current component approval and need to be reconciled before project use.

The Verea Spanish S table lists 81 ft-lbf for one-component StormBond with two 9.6 g paddies. StormBond 2 lists 83 ft-lbf with two 9.7 g paddies for that tile. These are separate published arrangements, not interchangeable product names.

Verea Spanish S NOA 25-0206.03 · page 5, Table 6 (opens in a new tab)
One-component StormBond NOA 26-0514.07 · installation requirements (opens in a new tab)

Roof height, shape, slope, edges and corners affect the required attachment. Your roofer and designer must match the chosen detail to those conditions, including the approval differences identified above.

How does StormBond 2 compare with APOC / ICP?

A useful comparison names the tile, plant, formulation and foam detail. Here, the same Westlake Saxony 900 Slate approval lists both StormBond 2 and APOC AH-160 HFC/HFO1 with a single 45 g paddy. The chart also lets you view TILE BOND’s different attachment patterns for that tile.

Published attachment values for the same tile

Choose an example. The printed weights identify entries in the tile approval; they are not jobsite dispensing instructions.

Two foams with the same Saxony 900 Slate tile

Listed attachment-resistance moment, Mf · ft-lbf · zero-based scale

DAP logo

StormBond 2 · two components

One 45 g paddy · tile-NOA table entry

93 ft-lbf
APOC logo

APOC AH-160 · HFC / HFO1

One 45 g paddy · tile-NOA table entry

119 ft-lbf

Lake Wales plant. Both rows specify one 45 g paddy. These are published tile-table entries, not dispensing instructions: contact area, location and each component approval still apply. AH-160’s value here belongs to HFC/HFO1, not HFO2. The roof’s required resistance must be checked separately.

NOA 24-1008.12, page 7, Table 6 (opens in a new tab)

What the number means: it describes resistance to the tile being rotated upward by wind in that approved detail. It is not a wind-speed rating or a direct measurement of how strongly every foam sticks to Polystick TU MAX. Different foam quantities and patterns prevent a simple brand ranking.

The decision for your house

Ask whether the chosen attachment meets the required resistance for your actual roof, including its edge and corner zones. A higher published value for a selected detail does not compensate for the wrong product, poor contact or damaged underlayment.

For more context, read our APOC Polyset AH-160 review and Westlake tile profile comparison. The charts here use the specific current documents linked beside them.

The workmanship details you can ask about

Fresh foam has a short setting window

The current component approvals specify tile placement within four minutes for StormBond and within one to two minutes for StormBond 2. These are crew quality-control requirements; they do not describe when the whole roof is finished or ready for a storm.

Cure claims have conditions

DAP’s StormBond 2 technical sheet gives a full-cure time of less than 24 hours under its stated conditions. Temperature, preparation and application instructions still matter. Cure time is separate from waterproofing, inspection and overall roof completion.

A repair needs more than a product swap

Have the roofer identify the existing tile and approved attachment before changing adhesives. A replacement tile also needs to fit correctly and be removed or reset without compromising the underlayment.

For an existing roof, our roof repair team can assess the visible issue and the work needed beneath it. A photo of a loose or broken tile cannot establish the condition of the whole roof.

Compare the full price—and who stands behind the work

Get estimates that name the same tile and full roofing scope. Check tear-off, wood-repair allowances, underlayment, flashing, tile and trim, attachment, permits and cleanup before deciding what a price difference means.

Product coverage and workmanship coverage

The linked DAP technical sheets describe a one-year limited warranty from purchase when the product is used as directed. The stated remedy is replacement product or a purchase-price refund, with incidental and consequential damages excluded. Ask for the current terms for the exact product and separate written workmanship coverage from the roofer, including who handles a leak or installation problem.

Use our Broward tile roof cost guide to plan the broader project, then get a written estimate for your home.

Frequently asked questions

Are StormBond and StormBond 2 the same adhesive?

No. StormBond is one component; StormBond 2 is a two-component system. They have separate Miami-Dade approvals and installation requirements. Have the estimate identify the exact product and formulation.

Can StormBond be used over Polystick TU MAX?

Polyglass NOA 25-0121.12 lists both DAP Storm Bond and Storm Bond 2 as compatible with Polystick TU MAX. Compatibility is one part of the roof system: the exact tile approval, adhesive detail and underlayment attachment must also match the project.

Is StormBond 2 stronger than APOC AH-160?

In the specific Saxony 900 Slate single-paddy example shown here, AH-160 HFC/HFO1 has the higher listed value at the same 45 g amount. That result does not establish a winner for every tile, formulation or roof. The specified assembly must meet the needs of your home.

Does a bigger foam paddy always mean better protection?

Use the approved pattern, amount, contact area and placement. Adding extra foam without an approved detail does not establish a new resistance value or fix missing waterproofing work.

Does curing in a day mean my roof replacement takes a day?

No. Adhesive cure is one part of installation. Preparation, underlayment, flashing, tile and trim work, weather and inspections have their own sequence. Ask for a schedule that separates active installation from final inspection.

What should a StormBond estimate include?

The exact adhesive version, tile profile, underlayment, approved attachment detail, preparation, flashing, repair allowances, permits and written coverage. That gives you a more useful comparison than the adhesive brand or kit price alone.

Which APOC / ICP products are included in the comparison?

Both Polyset RTA-1 and Polyset AH-160 are shown separately. RTA-1 uses one component; AH-160 uses two. They have different NOAs, foam amounts and attachment details. The graphs name the formulation and tile for each result. RTA-1 has no listed result in the two Verea clay approvals reviewed here, and differences between its component and tile instructions need to be resolved before project use.

What do the strength numbers in these graphs mean?

They are published attachment-resistance moments, measured in ft-lbf, for a specific tile and foam detail. A larger value means more listed resistance to that tile lifting and rotating in that arrangement. It is not a wind-speed rating or a direct test of the bond to Polystick TU MAX. Your roofer still needs to compare the chosen detail with your roof’s required wind resistance.

Sources checked October 22–23, 2026

Product approvals are revised and renewed. Confirm the current document for the exact product, plant and roof system when your permit is prepared. This guide is general information for homeowners, not an engineering or permit determination for a specific roof.