Tile adhesive review · DAP
StormBond: which version belongs in your tile roof estimate?
Review DAP StormBond and StormBond 2 for tile roofs, with current NOAs, Polystick TU MAX compatibility and graphs comparing APOC RTA-1, AH-160 and TILE BOND.
By M&M Roofing and Construction Corp · Florida Certified Roofing Contractor CCC1332459 · Published · Updated
Get a free tile roof estimate
Compare the tile, waterproofing and attachment included in a complete roof estimate.
The short answer
StormBond is worth considering as part of an approved tile roof system, but get the exact version in writing. StormBond uses one component; StormBond 2 uses two components mixed during application. They have separate approvals and installation requirements. The right choice is the detail that meets your roof’s needs and can be installed correctly.

Start with the whole roof
What should a homeowner care about?
The name on a quote needs to be more specific than “StormBond foam.” DAP sells a one-component StormBond product and a two-component StormBond 2 system. Both are polyurethane roof tile adhesives, but their handling and listed attachment results differ. The number 2 is a product distinction, not a strength grade.
Wind attachment is the useful question
Ask whether the specified system meets the wind demand for your roof’s shape and zones. A high number from another tile or foam pattern does not answer that question.
Installation timing deserves attention
The approved instructions give crews a short window to set tiles into fresh foam. Consistent handling, contact and placement matter because the product name alone cannot show how the work was done.
Keep waterproofing in the conversation
Foam attachment can be part of a good roof, but underlayment and flashing still need their own clear scope. Ask for photos and inspection records of the layers that will be hidden by the tile.
Four questions behind a good tile roof
Will the tile stay attached?
The approval needs to cover your exact tile and attachment pattern. Your roof’s corners, edges and field can have different demands. Ask which approved detail the estimate includes.
Ask your roofer
Can you show me the tile approval and the attachment plan for my roof?
Choosing the tile too? Browse tile colors and profiles and our tile roofing service guide alongside the attachment options.
StormBond and StormBond 2 are different products
The one-component and two-component products should appear as separate choices in an estimate. StormBond 2 needs the specified A/B mix, while the one-component product cures with moisture. Both component approvals require factory-trained, qualified applicators. Ask who will apply the adhesive and which product they are trained to use.
StormBond · one component
NOA 26-0514.07 (opens in a new tab)
- Approval date
- July 23, 2026
- Stated expiration
- July 21, 2031
Current approval includes StormBond and its Low GWP entry. It renews 23-0327.12; older technical sheets can still cite that earlier number.
Storm Bond 2 · two components
NOA 22-0512.02 (opens in a new tab)
- Approval date
- November 23, 2022
- Stated expiration
- April 13, 2027
Separate two-component approval. Confirm the HFC/HFO formulation, mixing equipment and approved tile detail for the product being supplied.
County status checked October 22, 2026: the component documents above are listed as File Approved. The tile’s own approval supplies attachment-resistance values. Read both together; a component NOA alone is not a design for your roof.

Our guide to checking a roofing product approval explains what to look for when comparing proposals.
The layer beneath your tile
Can it be used with Polystick TU MAX?
Yes—Polyglass’s compatibility table lists both DAP Storm Bond and Storm Bond 2 with Polystick TU MAX. The tile, foam detail and underlayment attachment still have to match the approved roof assembly.
Use the exact product name and formulation from the proposal and supplied kit when checking these documents.
Compatibility answers whether materials can be used together under the listed conditions. It does not replace the fastening or adhesion requirements beneath the membrane. Read our Polystick TU MAX review for the waterproofing side of the system.
Eight tile profiles · Four adhesive choices
How does StormBond 2 compare with RTA-1, AH-160 and TILE BOND?
Choose a tile below to compare all four products using that tile’s published approval. The graph covers flat and curved concrete tiles, one-piece clay and the separate Verea True Barrel cap-and-pan system. Each value links to its source page and table.
A “paddy” is a placed amount of foam; “headlap” is where the tiles overlap. The numbers measure resistance to the tile lifting and rotating, called Mf, in ft-lbf. They are not wind speeds or direct tests of the foam’s bond to Polystick TU MAX.
Two different APOC / ICP foams
Polyset RTA-1 · one component
APOC currently lists RTA-1 in cylinder and straw-foam formats. Its HFO component approval is NOA 25-1219.03 (opens in a new tab), with a stated expiration of January 3, 2027. The concrete-tile bars use the RTA-1 HFO rows.
Polyset AH-160 · two components
AH-160 has its own NOA 23-0614.01 (opens in a new tab), with a stated expiration of May 10, 2027. Its bars use the named HFC/HFO1 tile entries; True Barrel retains its legacy HFC identity. HFO2 is a separate formulation.
For Polystick TU MAX, the Polyglass compatibility table (opens in a new tab) names RTA-1 and AH-160 HFC. It does not separately establish RTA-1 HFO or AH-160 HFO1/HFO2 compatibility. Confirm the exact supplied product and complete roof assembly.
RTA-1 details need to be reconciled before project use
Some foam amounts and contact areas in the tile approvals differ from the current RTA-1 component approval, which also has differences between its table and drawings. The graph shows the published tile values. ICP and the roof designer need to resolve the applicable details before using them for your roof.
RTA-1 component NOA · Table 1 and drawings, pages 4–7 (opens in a new tab)
Compare the same tile
How do the attachment choices compare?
Choose a tile to see its published attachment values. A higher number means more listed resistance to that tile lifting and rotating in the named arrangement. Foam amounts and patterns can differ, so these are not equal-dose tests or a universal brand ranking.
Westlake · Flat concrete
Saxony 900 Slate
Tile NOA 24-1008.12 · page 6 · Table 5 (opens in a new tab)
Lake Wales, FL production covered by this tile NOA. The RTA-1 number is a published tile-table result. Its foam amount or contact detail needs reconciliation with the current component approval before project use.
Listed attachment resistance · Mf · ft-lbf
All bars start at zero. The scale stays from zero to 140 foot-pounds when changing tiles.

APOC Polyset RTA-1 · HFO
Two paddies: 12 g underlayment + 10 g headlap
41 ft-lbfSource entry · page 6 · Table 5 (opens in a new tab)
Mass and contact minimums align with the flat HFO drawing; tile row says 1 x 10 inch headlap while component drawing says 1 x 8 inch bead and minimum 10 in2 contact. Component Table 1 versus drawing conflict still needs resolution.

APOC Polyset AH-160 · HFC / HFO1
Single paddy: 45 g
119 ft-lbf
DuPont TILE BOND
Independent · two paddies: 25 g each
65 ft-lbfSource entry · page 6 · Table 5 (opens in a new tab)
The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation.

DAP StormBond 2
Two paddies: 8 g each
109 ft-lbf
View all tile values and sources in a table
| Tile | Adhesive | Mf · ft-lbf | Pattern and source |
|---|---|---|---|
| Westlake Saxony 900 SlateFlat concrete | APOC Polyset RTA-1 · HFO | 41 | Two paddies: 12 g underlayment + 10 g headlap Source · page 6 · Table 5 (opens in a new tab) Mass and contact minimums align with the flat HFO drawing; tile row says 1 x 10 inch headlap while component drawing says 1 x 8 inch bead and minimum 10 in2 contact. Component Table 1 versus drawing conflict still needs resolution. |
| Westlake Saxony 900 SlateFlat concrete | APOC Polyset AH-160 · HFC / HFO1 | 119 | Single paddy: 45 g |
| Westlake Saxony 900 SlateFlat concrete | DuPont TILE BOND | 65 | Independent · two paddies: 25 g each Source · page 6 · Table 5 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. |
| Westlake Saxony 900 SlateFlat concrete | DAP StormBond 2 | 109 | Two paddies: 8 g each |
| Crown Windsor SlateFlat concrete | APOC Polyset RTA-1 · HFO | 38 | Two paddies, 11 g each Source · page 7 · Table 5 (opens in a new tab) Tile row specifies 11 g each; component flat HFO drawing specifies 12 g underlayment and 10 g headlap. Contact is unspecified in tile table. Reconcile quantities and contact before installation. |
| Crown Windsor SlateFlat concrete | APOC Polyset AH-160 · HFC / HFO1 | 119 | Single paddy: 45 g |
| Crown Windsor SlateFlat concrete | DuPont TILE BOND | 65 | Independent · two paddies: 25 g each Source · page 7 · Table 5 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. |
| Crown Windsor SlateFlat concrete | DAP StormBond 2 | 122 | Two paddies: 8 g each |
| Westlake Villa 900Medium-profile concrete | APOC Polyset RTA-1 · HFO | 71 | Two paddies: 12 g underlayment + 10 g headlap Source · page 6 · Table 5 (opens in a new tab) Tile row headlap contact is 8 in2; component medium HFO drawing requires at least 10 in2. Mass matches the drawing, but contact detail needs reconciliation. |
| Westlake Villa 900Medium-profile concrete | APOC Polyset AH-160 · HFC / HFO1 | 87 | Single paddy: 54 g |
| Westlake Villa 900Medium-profile concrete | DuPont TILE BOND | 67 | Independent · two paddies: 25 g each Source · page 6 · Table 5 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. |
| Westlake Villa 900Medium-profile concrete | DAP StormBond 2 | 55 | Two paddies: 8 g each |
| Crown TuscanyMedium-profile concrete | APOC Polyset RTA-1 · HFO | 44.6 | Two paddies: 12 g underlayment + 10 g headlap Source · page 6 · Table 6 (opens in a new tab) Tile row headlap contact is 8 in2; component medium HFO drawing requires at least 10 in2. Mass matches the drawing, but contact detail needs reconciliation. |
| Crown TuscanyMedium-profile concrete | APOC Polyset AH-160 · HFC / HFO1 | 87 | Single paddy: 54 g |
| Crown TuscanyMedium-profile concrete | DuPont TILE BOND | 67 | Independent · two paddies: 25 g each Source · page 6 · Table 6 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. |
| Crown TuscanyMedium-profile concrete | DAP StormBond 2 | 108 | Two paddies: 8 g each |
| Westlake Barcelona 900High-profile concrete | APOC Polyset RTA-1 · HFO | 44 | Two paddies: 12 g underlayment + 12 g headlap Source · page 6 · Table 5 (opens in a new tab) Tile row headlap contact is 10 in2; component high HFO drawing requires at least 18 in2. Mass matches the drawing, but contact detail needs reconciliation. |
| Westlake Barcelona 900High-profile concrete | APOC Polyset AH-160 · HFC / HFO1 | 67 | Single paddy: 63 g |
| Westlake Barcelona 900High-profile concrete | DuPont TILE BOND | 58 | Independent · two paddies: 12.5 g each Source · page 6 · Table 5 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. |
| Westlake Barcelona 900High-profile concrete | DAP StormBond 2 | 66 | Two paddies: 8 g each |
| Crown SanibelHigh-profile concrete | APOC Polyset RTA-1 · HFO | 53.5 | Two paddies: 22 g underlayment + 11 g headlap Source · page 5 · Table 5 (opens in a new tab) Tile row has 22 g underlayment and 11 g headlap; component high HFO drawing specifies 12 g each. Headlap mass is below that drawing; tile contact is unspecified. Needs reconciliation. |
| Crown SanibelHigh-profile concrete | APOC Polyset AH-160 · HFC / HFO1 | 67 | Single paddy: 63 g |
| Crown SanibelHigh-profile concrete | DuPont TILE BOND | 58 | Independent · two paddies: 12.5 g each Source · page 5 · Table 5 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. |
| Crown SanibelHigh-profile concrete | DAP StormBond 2 | 101 | Two paddies: 8 g each |
| Verea Spanish S · Grade 1One-piece clay | APOC Polyset RTA-1 · HFO | Unavailable | No entry in the reviewed tile approval Source · page 5 · Tables 6–7 (opens in a new tab) No approval or performance value for this pairing is inferred from another tile. |
| Verea Spanish S · Grade 1One-piece clay | APOC Polyset AH-160 · HFC / HFO1 | 63 | Single paddy: 34.6 g |
| Verea Spanish S · Grade 1One-piece clay | DuPont TILE BOND | 54 | Independent · two paddies: 27.5 g each Source · page 5 · Table 6 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. |
| Verea Spanish S · Grade 1One-piece clay | DAP StormBond 2 | 83 | Two paddies: 9.7 g each |
| Verea True Barrel · Grade 1Two-piece clay | APOC Polyset RTA-1 · HFO | Unavailable | No entry in the reviewed tile approval Source · page 5 · Table 6 (opens in a new tab) No approval or performance value for this pairing is inferred from another tile. |
| Verea True Barrel · Grade 1Two-piece clay | ICP Polyset AH-160 · legacy HFC | 118.31 | 34.6 g per pan; 17.3 g on each side of cap Source · page 5 · Table 6 (opens in a new tab) Legacy Polyset AH-160 entry; not an HFO1 or HFO2 result. Table 6, footnote 3. |
| Verea True Barrel · Grade 1Two-piece clay | DuPont TILE BOND | 89.8 | 12.5 g per pan; 12.5 g on each side of cap Source · page 5 · Table 6 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. Table 6, footnote 4. |
| Verea True Barrel · Grade 1Two-piece clay | DAP StormBond 2 | Unavailable | No entry in the reviewed tile approval Source · page 5 · Table 6 (opens in a new tab) No approval or performance value for this pairing is inferred from another tile. |
Which attachment patterns are shown?
The main graph uses RTA-1 HFO two-paddy entries, AH-160 HFC/HFO1 single-paddy entries, TILE BOND independent entries and StormBond 2 two-paddy entries where listed. Foam amounts and patterns differ; these are selected published arrangements, not equal-dose tests or each brand’s maximum result. All tile choices use the same 0–140 scale.
True Barrel uses its own cap-and-pan arrangements and the legacy AH-160 HFC entry. RTA-1 has no listed value in the two reviewed Verea clay approvals; StormBond 2 has no listed value in the reviewed True Barrel table. Those gaps are left unplotted, not assigned a strength of zero.
What does this mean for your estimate?
For Saxony 900 Slate, the selected StormBond 2 two-paddy detail lists 109 ft-lbf and RTA-1 lists 41. For Villa 900, those selected entries list 55 and 71. Different foam amounts and contact details are involved. The useful question is which exact tile-and-attachment arrangement meets your home’s requirements.
What about one-component StormBond?
The main comparison uses StormBond 2, the two-component product. One-component StormBond has separate values and application requirements. Several concrete-tile entries differ from the minimums in its current component approval and need to be reconciled before project use.
The Verea Spanish S table lists 81 ft-lbf for one-component StormBond with two 9.6 g paddies. StormBond 2 lists 83 ft-lbf with two 9.7 g paddies for that tile. These are separate published arrangements, not interchangeable product names.
Verea Spanish S NOA 25-0206.03 · page 5, Table 6 (opens in a new tab)
One-component StormBond NOA 26-0514.07 · installation requirements (opens in a new tab)
Roof height, shape, slope, edges and corners affect the required attachment. Your roofer and designer must match the chosen detail to those conditions, including the approval differences identified above.
How does StormBond 2 compare with APOC / ICP?
A useful comparison names the tile, plant, formulation and foam detail. Here, the same Westlake Saxony 900 Slate approval lists both StormBond 2 and APOC AH-160 HFC/HFO1 with a single 45 g paddy. The chart also lets you view TILE BOND’s different attachment patterns for that tile.
Published attachment values for the same tile
Choose an example. The printed weights identify entries in the tile approval; they are not jobsite dispensing instructions.
Two foams with the same Saxony 900 Slate tile
Listed attachment-resistance moment, Mf · ft-lbf · zero-based scale
StormBond 2 · two components
One 45 g paddy · tile-NOA table entry
APOC AH-160 · HFC / HFO1
One 45 g paddy · tile-NOA table entry
Lake Wales plant. Both rows specify one 45 g paddy. These are published tile-table entries, not dispensing instructions: contact area, location and each component approval still apply. AH-160’s value here belongs to HFC/HFO1, not HFO2. The roof’s required resistance must be checked separately.
The decision for your house
Ask whether the chosen attachment meets the required resistance for your actual roof, including its edge and corner zones. A higher published value for a selected detail does not compensate for the wrong product, poor contact or damaged underlayment.
For more context, read our APOC Polyset AH-160 review and Westlake tile profile comparison. The charts here use the specific current documents linked beside them.
The workmanship details you can ask about
Fresh foam has a short setting window
The current component approvals specify tile placement within four minutes for StormBond and within one to two minutes for StormBond 2. These are crew quality-control requirements; they do not describe when the whole roof is finished or ready for a storm.
Cure claims have conditions
DAP’s StormBond 2 technical sheet gives a full-cure time of less than 24 hours under its stated conditions. Temperature, preparation and application instructions still matter. Cure time is separate from waterproofing, inspection and overall roof completion.
A repair needs more than a product swap
Have the roofer identify the existing tile and approved attachment before changing adhesives. A replacement tile also needs to fit correctly and be removed or reset without compromising the underlayment.
For an existing roof, our roof repair team can assess the visible issue and the work needed beneath it. A photo of a loose or broken tile cannot establish the condition of the whole roof.
Compare the full price—and who stands behind the work
Get estimates that name the same tile and full roofing scope. Check tear-off, wood-repair allowances, underlayment, flashing, tile and trim, attachment, permits and cleanup before deciding what a price difference means.
Product coverage and workmanship coverage
The linked DAP technical sheets describe a one-year limited warranty from purchase when the product is used as directed. The stated remedy is replacement product or a purchase-price refund, with incidental and consequential damages excluded. Ask for the current terms for the exact product and separate written workmanship coverage from the roofer, including who handles a leak or installation problem.
Use our Broward tile roof cost guide to plan the broader project, then get a written estimate for your home.
Frequently asked questions
Are StormBond and StormBond 2 the same adhesive?
No. StormBond is one component; StormBond 2 is a two-component system. They have separate Miami-Dade approvals and installation requirements. Have the estimate identify the exact product and formulation.
Can StormBond be used over Polystick TU MAX?
Polyglass NOA 25-0121.12 lists both DAP Storm Bond and Storm Bond 2 as compatible with Polystick TU MAX. Compatibility is one part of the roof system: the exact tile approval, adhesive detail and underlayment attachment must also match the project.
Is StormBond 2 stronger than APOC AH-160?
In the specific Saxony 900 Slate single-paddy example shown here, AH-160 HFC/HFO1 has the higher listed value at the same 45 g amount. That result does not establish a winner for every tile, formulation or roof. The specified assembly must meet the needs of your home.
Does a bigger foam paddy always mean better protection?
Use the approved pattern, amount, contact area and placement. Adding extra foam without an approved detail does not establish a new resistance value or fix missing waterproofing work.
Does curing in a day mean my roof replacement takes a day?
No. Adhesive cure is one part of installation. Preparation, underlayment, flashing, tile and trim work, weather and inspections have their own sequence. Ask for a schedule that separates active installation from final inspection.
What should a StormBond estimate include?
The exact adhesive version, tile profile, underlayment, approved attachment detail, preparation, flashing, repair allowances, permits and written coverage. That gives you a more useful comparison than the adhesive brand or kit price alone.
Which APOC / ICP products are included in the comparison?
Both Polyset RTA-1 and Polyset AH-160 are shown separately. RTA-1 uses one component; AH-160 uses two. They have different NOAs, foam amounts and attachment details. The graphs name the formulation and tile for each result. RTA-1 has no listed result in the two Verea clay approvals reviewed here, and differences between its component and tile instructions need to be resolved before project use.
What do the strength numbers in these graphs mean?
They are published attachment-resistance moments, measured in ft-lbf, for a specific tile and foam detail. A larger value means more listed resistance to that tile lifting and rotating in that arrangement. It is not a wind-speed rating or a direct test of the bond to Polystick TU MAX. Your roofer still needs to compare the chosen detail with your roof’s required wind resistance.
Sources checked October 22–23, 2026
- APOC 705 Polyset RTA-1 · manufacturer product page (opens in a new tab)Product identity, currently listed packaging and original manufacturer product image. Listing checked October 23, 2026; local stock not established.
- RTA-1 · component NOA 25-1219.03 (opens in a new tab)Approved January 29, 2026; stated expiration January 3, 2027. Installer qualifications, four-minute placement window and component attachment details. Table 1 and HFO drawings contain differences described in this review.
- Miami-Dade current file status · RTA-1 (opens in a new tab)File Approved when checked October 23, 2026. Recheck status and any successor document when specifying a project.
- Polyglass underlayments · NOA 25-0121.12 (opens in a new tab)Page 18: Polystick TU MAX compatibility table includes APOC Polyset RTA-1 without a separate HFO designation.
- APOC Polyset AH-160 · component NOA 23-0614.01 (opens in a new tab)Separate two-component adhesive. Concrete and Spanish S chart rows use HFC/HFO1; the True Barrel row retains its legacy HFC identity. HFO2 values are not substituted.
- TILE BOND · component NOA 26-0306.01 (opens in a new tab)Current component requirements. Tile-table product labels, foam quantities and independent attachment details remain visible in the comparison.
- StormBond 2 · component NOA 22-0512.02 (opens in a new tab)Two-component product used in the graphs; its component approval permits tile-specific application details. Separate from one-component StormBond.
- Westlake Saxony 900 Slate · tile NOA 24-1008.12 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- Crown Windsor Slate · tile NOA 25-0127.10 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- Westlake Villa 900 · tile NOA 26-0602.02 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- Crown Tuscany · tile NOA 25-0127.09 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- Westlake Barcelona 900 · tile NOA 24-1008.13 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- Crown Sanibel · tile NOA 24-1008.16 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- Verea Spanish S · Grade 1 · tile NOA 25-0206.03 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- Verea True Barrel · Grade 1 · tile NOA 22-1202.03 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- DAP Storm Bond 2 product information (opens in a new tab)Current two-component product page, technical sheet links, packaging and original DAP application photographs.
- DAP one-component StormBond product information (opens in a new tab)Manufacturer’s legacy product page identifies the single-component product. Use the newer county approval below for current acceptance.
- StormBond · current NOA 26-0514.07 (opens in a new tab)One-component approval, including placement time and installer qualifications. Approved July 23, 2026; expires July 21, 2031.
- StormBond 2 technical data sheet (opens in a new tab)Page 2: curing and handling conditions; page 4: limited product warranty. Product instructions are separate from the roof’s completion schedule.
- One-component StormBond Low GWP technical sheet (opens in a new tab)Product handling and page 4 warranty. This sheet cites earlier NOAs; current acceptance is documented by county NOA 26-0514.07 above.
Product approvals are revised and renewed. Confirm the current document for the exact product, plant and roof system when your permit is prepared. This guide is general information for homeowners, not an engineering or permit determination for a specific roof.
Let’s compare the complete roof for your home
Talk through tile choices, waterproofing, approved attachment and the work included in your estimate.
Call (754) 714-8445