Tile adhesive review · DuPont
TILE BOND: what this roof tile adhesive means for your home
Review DuPont TILE BOND for tile roofing, with current NOAs, Polystick TU MAX compatibility and graphs comparing APOC RTA-1, AH-160 and StormBond 2.
By M&M Roofing and Construction Corp · Florida Certified Roofing Contractor CCC1332459 · Published · Updated
Get a free tile roof estimate
Compare the tile, waterproofing and attachment included in a complete roof estimate.
The short answer
TILE BOND can be a practical way to attach clay or concrete roof tiles when it is part of an approved roof system. Its one-component format avoids mixing two chemicals on the roof. For your home, the bigger questions are whether the attachment meets your roof’s wind requirements and how the waterproofing beneath the tile will be installed.

Start with the whole roof
What should a homeowner care about?
TILE BOND is a one-component polyurethane foam adhesive used with approved clay and concrete roof tiles. DuPont describes it as moisture-cured and low-expansion. It is the attachment layer in a larger system: tile, adhesive, underlayment, flashings and wood decking all have different jobs.
A simpler product format
One component means there is no A/B mixing ratio to manage during application. The crew still needs to control surface preparation, foam placement and the time between dispensing and setting the tile.
Fewer field-tile fasteners may be possible
A compatible foam-set detail can reduce fasteners through the field tiles. Edge, trim and steep-slope requirements still need to be checked, so a quote should explain the entire attachment scope.
The roof system decides the fit
Ask the roofer to match TILE BOND to the actual tile profile, underlayment and roof conditions. A product being approved does not make every combination of roofing materials an approved assembly.
Four questions behind a good tile roof
Will the tile stay attached?
The approval needs to cover your exact tile and attachment pattern. Your roof’s corners, edges and field can have different demands. Ask which approved detail the estimate includes.
Ask your roofer
Can you show me the tile approval and the attachment plan for my roof?
Choosing the tile too? Browse tile colors and profiles and our tile roofing service guide alongside the attachment options.
Make sure the estimate names the right product
The approval describes independent and interdependent attachment. In plain terms, an independent detail bonds the tile through its own underlayment contact; an interdependent detail also uses the overlap with the course below. That is why two similar foam quantities can represent different ways of carrying wind loads.
TILE BOND / TILE BOND (HFO)
NOA 26-0306.01 (opens in a new tab)
- Approval date
- August 20, 2026
- Stated expiration
- August 23, 2031
Current component approval covers the original and HFO products. It renews 22-0614.05, so older online references should not be used as the current document.
County status checked October 22, 2026: the component documents above are listed as File Approved. The tile’s own approval supplies attachment-resistance values. Read both together; a component NOA alone is not a design for your roof.
Our guide to checking a roofing product approval explains what to look for when comparing proposals.
The layer beneath your tile
Can it be used with Polystick TU MAX?
Yes—Polyglass’s compatibility table lists DuPont TILE BOND with Polystick TU MAX. Confirm the exact adhesive formulation and the complete assembly before treating that as approval for your roof.
The table names TILE BOND without a separate HFO label. The component approval’s inclusion of HFO does not, by itself, settle every formulation and underlayment combination.
Compatibility answers whether materials can be used together under the listed conditions. It does not replace the fastening or adhesion requirements beneath the membrane. Read our Polystick TU MAX review for the waterproofing side of the system.
Eight tile profiles · Four adhesive choices
How does TILE BOND compare with RTA-1, AH-160 and StormBond 2?
Choose a tile below to compare all four products using that tile’s published approval. The graph covers flat and curved concrete tiles, one-piece clay and the separate Verea True Barrel cap-and-pan system. Each value links to its source page and table.
A “paddy” is a placed amount of foam; “headlap” is where the tiles overlap. The numbers measure resistance to the tile lifting and rotating, called Mf, in ft-lbf. They are not wind speeds or direct tests of the foam’s bond to Polystick TU MAX.
Two different APOC / ICP foams
Polyset RTA-1 · one component
APOC currently lists RTA-1 in cylinder and straw-foam formats. Its HFO component approval is NOA 25-1219.03 (opens in a new tab), with a stated expiration of January 3, 2027. The concrete-tile bars use the RTA-1 HFO rows.
Polyset AH-160 · two components
AH-160 has its own NOA 23-0614.01 (opens in a new tab), with a stated expiration of May 10, 2027. Its bars use the named HFC/HFO1 tile entries; True Barrel retains its legacy HFC identity. HFO2 is a separate formulation.
For Polystick TU MAX, the Polyglass compatibility table (opens in a new tab) names RTA-1 and AH-160 HFC. It does not separately establish RTA-1 HFO or AH-160 HFO1/HFO2 compatibility. Confirm the exact supplied product and complete roof assembly.
RTA-1 details need to be reconciled before project use
Some foam amounts and contact areas in the tile approvals differ from the current RTA-1 component approval, which also has differences between its table and drawings. The graph shows the published tile values. ICP and the roof designer need to resolve the applicable details before using them for your roof.
RTA-1 component NOA · Table 1 and drawings, pages 4–7 (opens in a new tab)
Compare the same tile
How do the attachment choices compare?
Choose a tile to see its published attachment values. A higher number means more listed resistance to that tile lifting and rotating in the named arrangement. Foam amounts and patterns can differ, so these are not equal-dose tests or a universal brand ranking.
Westlake · Flat concrete
Saxony 900 Slate
Tile NOA 24-1008.12 · page 6 · Table 5 (opens in a new tab)
Lake Wales, FL production covered by this tile NOA. The RTA-1 number is a published tile-table result. Its foam amount or contact detail needs reconciliation with the current component approval before project use.
Listed attachment resistance · Mf · ft-lbf
All bars start at zero. The scale stays from zero to 140 foot-pounds when changing tiles.

APOC Polyset RTA-1 · HFO
Two paddies: 12 g underlayment + 10 g headlap
41 ft-lbfSource entry · page 6 · Table 5 (opens in a new tab)
Mass and contact minimums align with the flat HFO drawing; tile row says 1 x 10 inch headlap while component drawing says 1 x 8 inch bead and minimum 10 in2 contact. Component Table 1 versus drawing conflict still needs resolution.

APOC Polyset AH-160 · HFC / HFO1
Single paddy: 45 g
119 ft-lbf
DuPont TILE BOND
Independent · two paddies: 25 g each
65 ft-lbfSource entry · page 6 · Table 5 (opens in a new tab)
The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation.

DAP StormBond 2
Two paddies: 8 g each
109 ft-lbf
View all tile values and sources in a table
| Tile | Adhesive | Mf · ft-lbf | Pattern and source |
|---|---|---|---|
| Westlake Saxony 900 SlateFlat concrete | APOC Polyset RTA-1 · HFO | 41 | Two paddies: 12 g underlayment + 10 g headlap Source · page 6 · Table 5 (opens in a new tab) Mass and contact minimums align with the flat HFO drawing; tile row says 1 x 10 inch headlap while component drawing says 1 x 8 inch bead and minimum 10 in2 contact. Component Table 1 versus drawing conflict still needs resolution. |
| Westlake Saxony 900 SlateFlat concrete | APOC Polyset AH-160 · HFC / HFO1 | 119 | Single paddy: 45 g |
| Westlake Saxony 900 SlateFlat concrete | DuPont TILE BOND | 65 | Independent · two paddies: 25 g each Source · page 6 · Table 5 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. |
| Westlake Saxony 900 SlateFlat concrete | DAP StormBond 2 | 109 | Two paddies: 8 g each |
| Crown Windsor SlateFlat concrete | APOC Polyset RTA-1 · HFO | 38 | Two paddies, 11 g each Source · page 7 · Table 5 (opens in a new tab) Tile row specifies 11 g each; component flat HFO drawing specifies 12 g underlayment and 10 g headlap. Contact is unspecified in tile table. Reconcile quantities and contact before installation. |
| Crown Windsor SlateFlat concrete | APOC Polyset AH-160 · HFC / HFO1 | 119 | Single paddy: 45 g |
| Crown Windsor SlateFlat concrete | DuPont TILE BOND | 65 | Independent · two paddies: 25 g each Source · page 7 · Table 5 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. |
| Crown Windsor SlateFlat concrete | DAP StormBond 2 | 122 | Two paddies: 8 g each |
| Westlake Villa 900Medium-profile concrete | APOC Polyset RTA-1 · HFO | 71 | Two paddies: 12 g underlayment + 10 g headlap Source · page 6 · Table 5 (opens in a new tab) Tile row headlap contact is 8 in2; component medium HFO drawing requires at least 10 in2. Mass matches the drawing, but contact detail needs reconciliation. |
| Westlake Villa 900Medium-profile concrete | APOC Polyset AH-160 · HFC / HFO1 | 87 | Single paddy: 54 g |
| Westlake Villa 900Medium-profile concrete | DuPont TILE BOND | 67 | Independent · two paddies: 25 g each Source · page 6 · Table 5 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. |
| Westlake Villa 900Medium-profile concrete | DAP StormBond 2 | 55 | Two paddies: 8 g each |
| Crown TuscanyMedium-profile concrete | APOC Polyset RTA-1 · HFO | 44.6 | Two paddies: 12 g underlayment + 10 g headlap Source · page 6 · Table 6 (opens in a new tab) Tile row headlap contact is 8 in2; component medium HFO drawing requires at least 10 in2. Mass matches the drawing, but contact detail needs reconciliation. |
| Crown TuscanyMedium-profile concrete | APOC Polyset AH-160 · HFC / HFO1 | 87 | Single paddy: 54 g |
| Crown TuscanyMedium-profile concrete | DuPont TILE BOND | 67 | Independent · two paddies: 25 g each Source · page 6 · Table 6 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. |
| Crown TuscanyMedium-profile concrete | DAP StormBond 2 | 108 | Two paddies: 8 g each |
| Westlake Barcelona 900High-profile concrete | APOC Polyset RTA-1 · HFO | 44 | Two paddies: 12 g underlayment + 12 g headlap Source · page 6 · Table 5 (opens in a new tab) Tile row headlap contact is 10 in2; component high HFO drawing requires at least 18 in2. Mass matches the drawing, but contact detail needs reconciliation. |
| Westlake Barcelona 900High-profile concrete | APOC Polyset AH-160 · HFC / HFO1 | 67 | Single paddy: 63 g |
| Westlake Barcelona 900High-profile concrete | DuPont TILE BOND | 58 | Independent · two paddies: 12.5 g each Source · page 6 · Table 5 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. |
| Westlake Barcelona 900High-profile concrete | DAP StormBond 2 | 66 | Two paddies: 8 g each |
| Crown SanibelHigh-profile concrete | APOC Polyset RTA-1 · HFO | 53.5 | Two paddies: 22 g underlayment + 11 g headlap Source · page 5 · Table 5 (opens in a new tab) Tile row has 22 g underlayment and 11 g headlap; component high HFO drawing specifies 12 g each. Headlap mass is below that drawing; tile contact is unspecified. Needs reconciliation. |
| Crown SanibelHigh-profile concrete | APOC Polyset AH-160 · HFC / HFO1 | 67 | Single paddy: 63 g |
| Crown SanibelHigh-profile concrete | DuPont TILE BOND | 58 | Independent · two paddies: 12.5 g each Source · page 5 · Table 5 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. |
| Crown SanibelHigh-profile concrete | DAP StormBond 2 | 101 | Two paddies: 8 g each |
| Verea Spanish S · Grade 1One-piece clay | APOC Polyset RTA-1 · HFO | Unavailable | No entry in the reviewed tile approval Source · page 5 · Tables 6–7 (opens in a new tab) No approval or performance value for this pairing is inferred from another tile. |
| Verea Spanish S · Grade 1One-piece clay | APOC Polyset AH-160 · HFC / HFO1 | 63 | Single paddy: 34.6 g |
| Verea Spanish S · Grade 1One-piece clay | DuPont TILE BOND | 54 | Independent · two paddies: 27.5 g each Source · page 5 · Table 6 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. |
| Verea Spanish S · Grade 1One-piece clay | DAP StormBond 2 | 83 | Two paddies: 9.7 g each |
| Verea True Barrel · Grade 1Two-piece clay | APOC Polyset RTA-1 · HFO | Unavailable | No entry in the reviewed tile approval Source · page 5 · Table 6 (opens in a new tab) No approval or performance value for this pairing is inferred from another tile. |
| Verea True Barrel · Grade 1Two-piece clay | ICP Polyset AH-160 · legacy HFC | 118.31 | 34.6 g per pan; 17.3 g on each side of cap Source · page 5 · Table 6 (opens in a new tab) Legacy Polyset AH-160 entry; not an HFO1 or HFO2 result. Table 6, footnote 3. |
| Verea True Barrel · Grade 1Two-piece clay | DuPont TILE BOND | 89.8 | 12.5 g per pan; 12.5 g on each side of cap Source · page 5 · Table 6 (opens in a new tab) The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. Table 6, footnote 4. |
| Verea True Barrel · Grade 1Two-piece clay | DAP StormBond 2 | Unavailable | No entry in the reviewed tile approval Source · page 5 · Table 6 (opens in a new tab) No approval or performance value for this pairing is inferred from another tile. |
Which attachment patterns are shown?
The main graph uses RTA-1 HFO two-paddy entries, AH-160 HFC/HFO1 single-paddy entries, TILE BOND independent entries and StormBond 2 two-paddy entries where listed. Foam amounts and patterns differ; these are selected published arrangements, not equal-dose tests or each brand’s maximum result. All tile choices use the same 0–140 scale.
True Barrel uses its own cap-and-pan arrangements and the legacy AH-160 HFC entry. RTA-1 has no listed value in the two reviewed Verea clay approvals; StormBond 2 has no listed value in the reviewed True Barrel table. Those gaps are left unplotted, not assigned a strength of zero.
What does this mean for your estimate?
For Saxony 900 Slate, the selected TILE BOND detail lists 65 ft-lbf and the RTA-1 detail lists 41. For Villa 900, those entries list 67 and 71. The comparison changes with the tile and attachment pattern. Ask which exact detail meets the requirements for your roof instead of choosing a brand from one bar.
Roof height, shape, slope, edges and corners affect the required attachment. Your roofer and designer must match the chosen detail to those conditions, including the approval differences identified above.
How does TILE BOND compare with the other foams?
Start with a tile that lists the products you are comparing. The examples below use Westlake Saxony 900 Slate from the Lake Wales plant. TILE BOND has its own independent and interdependent details; they are not the same pattern or foam amount as the single-paddy StormBond 2 and APOC AH-160 example.
Published attachment values for the same tile
Choose an example. The printed weights identify entries in the tile approval; they are not jobsite dispensing instructions.
TILE BOND with Westlake Saxony 900 Slate
Listed attachment-resistance moment, Mf · ft-lbf · zero-based scale
TILE BOND
Interdependent · two paddies, 12.5 g each
TILE BOND
Independent · two paddies, 25 g each
Lake Wales plant. These two entries use different load paths and foam quantities. Interdependent attachment includes a bond at the tile overlap; independent attachment uses the tile’s own underlayment contacts. The small difference between these values is not a reason to change the specified pattern.
The decision for your house
Ask whether the chosen attachment meets the required resistance for your actual roof, including its edge and corner zones. A higher published value for a selected detail does not compensate for the wrong product, poor contact or damaged underlayment.
For more context, read our APOC Polyset AH-160 review and Westlake tile profile comparison. The charts here use the specific current documents linked beside them.
The workmanship details you can ask about
Surface condition matters
Moisture-cured does not mean that any wet, dirty or damaged roof is ready for tile. The crew must follow the adhesive and underlayment instructions for the actual surface conditions.
Placement is part of the approval
Foam amount, contact area and position work together. Ask how those details are checked during installation. A large-looking blob in a photograph does not establish its approved attachment resistance.
Repairs need the same care
A convenient can or cylinder does not make a loose-tile repair simply a matter of adding foam. The cause of movement, tile condition, surrounding roof and underlayment need to be assessed first.
For an existing roof, our roof repair team can assess the visible issue and the work needed beneath it. A photo of a loose or broken tile cannot establish the condition of the whole roof.
Compare the full price—and who stands behind the work
Get estimates that name the same tile and full roofing scope. Check tear-off, wood-repair allowances, underlayment, flashing, tile and trim, attachment, permits and cleanup before deciding what a price difference means.
Product coverage and workmanship coverage
Ask for both the current product warranty and the contractor’s workmanship terms. The TILE BOND installation manual describes a limited manufacturing-defect warranty for one year from manufacture, with a product-price credit remedy at DuPont’s discretion. That wording is not a promise to pay for roof tear-off, labor or leak damage. The written terms supplied for your product control.
Use our Broward tile roof cost guide to plan the broader project, then get a written estimate for your home.
Frequently asked questions
Is TILE BOND a good choice for a South Florida tile roof?
It can be, when the approved tile, adhesive and underlayment details meet the requirements for your roof. Ask for the exact product and attachment detail in the estimate, along with the waterproofing and workmanship scope.
Can TILE BOND be used with Polystick TU MAX?
Polyglass NOA 25-0121.12 lists DuPont TILE BOND as compatible with Polystick TU MAX. That table does not separately name TILE BOND (HFO). Have the roofer confirm the supplied formulation and complete approved assembly rather than assume every version is interchangeable.
Is TILE BOND stronger than APOC or StormBond?
There is no useful all-roofs winner. The same tile approval lists different foam amounts and attachment patterns. Compare the exact entries and check whether the selected detail meets the wind demand for your home.
Will foam attachment stop roof leaks?
Foam holds the tiles in place. Underlayment, flashings and their connections provide the waterproofing beneath the tile. Both attachment and waterproofing need to be included in a complete roof estimate.
Does a foam-set roof have no nails or screws?
Not necessarily. Approved details can still require mechanical attachment at certain locations or slopes. Ask which parts of the roof use foam and where fasteners or other attachment are required.
Is TILE BOND cheaper for my roof?
A canister price does not establish the installed roof price. Roof geometry, selected tile, approved foam pattern, preparation, access and labor affect the proposal. Compare itemized estimates for the same complete scope.
Which APOC / ICP products are included in the comparison?
Both Polyset RTA-1 and Polyset AH-160 are shown separately. RTA-1 uses one component; AH-160 uses two. They have different NOAs, foam amounts and attachment details. The graphs name the formulation and tile for each result. RTA-1 has no listed result in the two Verea clay approvals reviewed here, and differences between its component and tile instructions need to be resolved before project use.
What do the strength numbers in these graphs mean?
They are published attachment-resistance moments, measured in ft-lbf, for a specific tile and foam detail. A larger value means more listed resistance to that tile lifting and rotating in that arrangement. It is not a wind-speed rating or a direct test of the bond to Polystick TU MAX. Your roofer still needs to compare the chosen detail with your roof’s required wind resistance.
Sources checked October 22–23, 2026
- APOC 705 Polyset RTA-1 · manufacturer product page (opens in a new tab)Product identity, currently listed packaging and original manufacturer product image. Listing checked October 23, 2026; local stock not established.
- RTA-1 · component NOA 25-1219.03 (opens in a new tab)Approved January 29, 2026; stated expiration January 3, 2027. Installer qualifications, four-minute placement window and component attachment details. Table 1 and HFO drawings contain differences described in this review.
- Miami-Dade current file status · RTA-1 (opens in a new tab)File Approved when checked October 23, 2026. Recheck status and any successor document when specifying a project.
- Polyglass underlayments · NOA 25-0121.12 (opens in a new tab)Page 18: Polystick TU MAX compatibility table includes APOC Polyset RTA-1 without a separate HFO designation.
- APOC Polyset AH-160 · component NOA 23-0614.01 (opens in a new tab)Separate two-component adhesive. Concrete and Spanish S chart rows use HFC/HFO1; the True Barrel row retains its legacy HFC identity. HFO2 values are not substituted.
- TILE BOND · component NOA 26-0306.01 (opens in a new tab)Current component requirements. Tile-table product labels, foam quantities and independent attachment details remain visible in the comparison.
- StormBond 2 · component NOA 22-0512.02 (opens in a new tab)Two-component product used in the graphs; its component approval permits tile-specific application details. Separate from one-component StormBond.
- Westlake Saxony 900 Slate · tile NOA 24-1008.12 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- Crown Windsor Slate · tile NOA 25-0127.10 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- Westlake Villa 900 · tile NOA 26-0602.02 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- Crown Tuscany · tile NOA 25-0127.09 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- Westlake Barcelona 900 · tile NOA 24-1008.13 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- Crown Sanibel · tile NOA 24-1008.16 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- Verea Spanish S · Grade 1 · tile NOA 25-0206.03 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- Verea True Barrel · Grade 1 · tile NOA 22-1202.03 (opens in a new tab)Specific tile approval used for the graph. Each bar links to its exact page and table. County file status checked October 23, 2026.
- DuPont TILE BOND product information (opens in a new tab)Product identity, one-component format, moisture curing, packaging and original manufacturer imagery.
- DuPont TILE BOND installation manual (opens in a new tab)Page 2: limited manufacturing-defect warranty and installer qualifications. Use current component and tile approvals alongside the manual.
Product approvals are revised and renewed. Confirm the current document for the exact product, plant and roof system when your permit is prepared. This guide is general information for homeowners, not an engineering or permit determination for a specific roof.
Let’s compare the complete roof for your home
Talk through tile choices, waterproofing, approved attachment and the work included in your estimate.
Call (754) 714-8445