Top 5 tile roof foam adhesives, ranked by strength

See how five tile roof foams rank for your tile, using Miami-Dade NOA attachment values, clear comparisons and questions to ask your roofer.

By M&M Roofing and Construction Corp · Florida Certified Roofing Contractor CCC1332459 · Published · Updated

Get a free tile roof estimate

Compare the tile, attachment and waterproofing specified for your home.

Add project details (optional)

No obligation. We use your details to respond to this request.

Prefer to speak now? (754) 714-8445

The short answer

Want to know which foam holds roof tiles best? Start with the tile you’re choosing. In the attachment details we reviewed, AH-160 leads for Westlake Saxony 900 Slate, while StormBond 2 leads for Crown Windsor Slate. No foam wins for every tile. Choose your profile below to see the order, then ask your roofer to confirm that the exact product and attachment detail meet your home’s wind requirements.

Flat-profile concrete roof tile installation with medium APOC Polyset foam adhesive paddies on underlayment.
Foam attachment on a real M&M Roofing job: APOC Polyset adhesive beneath flat-profile tiles. This photo illustrates the work, not a five-product test or proof of the attachment values below.

Strength ranking · Choose the tile first

Which of these five foams holds your tile best?

A tile can catch wind and try to lift and rotate. The values below describe how much resistance a listed tile-and-foam arrangement provides against that movement. A higher number means more listed resistance for that arrangement.

The five products are APOC Polyset AH-160, APOC Polyset RTA-1, DuPont TILE BOND, DAP StormBond and DAP StormBond 2. StormBond and StormBond 2 are different products. We compare all five where the tile approvals provide a clear entry.

The measurement is called Mf, in ft-lbf. It is not a wind-speed rating or a direct test of the foam’s bond to Polystick TU MAX. The foam amounts and placement differ, so this ranks documented attachment arrangements rather than equal amounts of foam.

The ranking changes with the tile

Which foam ranks highest for your tile?

We rank the highest verified, unambiguous foam-only entries in the cited tile tables. These arrangements use different foam amounts and patterns; the order is not an equal-dose test or a ranking of every possible roof system.

Westlake · Flat concrete

Saxony 900 Slate

APOC Polyset AH-160 · HFC / HFO1 has the highest ranked value here: 119 ft-lbf. This result belongs to the listed formulation and attachment detail.

Lake Wales, FL production covered by this tile NOA. The RTA-1 number is a published tile-table result. Its foam amount or contact detail needs reconciliation with the current component approval before project use. The one-component StormBond row also differs from current component application minimums and requires reconciliation before project use.

Listed attachment resistance · Mf · ft-lbf

Higher means more listed resistance to the tile lifting and rotating in that arrangement. It does not mean a particular wind speed.

All bars start at zero and use the same zero to 140 foot-pound scale across tile profiles.

  1. 1
    APOC logo
    APOC Polyset AH-160 · HFC / HFO1
    119 ft-lbf
    Attachment detail and NOA

    Single paddy: 45 g

    Tile NOA 24-1008.12 · page 7 · Table 6 (opens in a new tab)

  2. 2
    DAP logo
    DAP StormBond 2
    109 ft-lbf
    Attachment detail and NOA

    Two paddies: 8 g each

    Tile NOA 24-1008.12 · page 6 · Table 5 (opens in a new tab)

  3. 3
    DuPont logo
    DuPont TILE BOND
    65 ft-lbf
    Attachment detail and NOA · notes to check

    Independent · two paddies: 25 g each

    Tile NOA 24-1008.12 · page 6 · Table 5 (opens in a new tab)

    The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation.

  4. 4
    DAP logo
    DAP StormBond · one component
    59 ft-lbf
    Attachment detail and NOA · notes to check

    Two paddies: 8 g each

    Tile NOA 24-1008.12 · page 6 · Table 5 (opens in a new tab)

    Below component flat/low minima 10.2 g at head and 18.3 g on side. The tile row names StormBond without a formulation designation; its amounts also fall below the separate Low GWP component details. DAP and the roof designer must reconcile the applicable formulation and installation requirements before project use. These are published values, not jobsite dispensing instructions.

  5. 5
    APOC logo
    APOC Polyset RTA-1 · HFO
    41 ft-lbf
    Attachment detail and NOA · notes to check

    Two paddies: 12 g underlayment + 10 g headlap

    Tile NOA 24-1008.12 · page 6 · Table 5 (opens in a new tab)

    Mass and contact minimums align with the flat HFO drawing; tile row says 1 x 10 inch headlap while component drawing says 1 x 8 inch bead and minimum 10 in2 contact. Component Table 1 versus drawing conflict still needs resolution.

Use the whole detail. Foam quantities identify the source entries; they are not dispensing instructions. The current component approval, exact tile, underlayment and roof design must agree before an attachment detail is used.
See all tile rankings and source entries
Five tile foam products ranked for each tile using verified published attachment details. Missing values remain unranked.
TileRankFoam and formulationMf · ft-lbfPattern and source
Westlake Saxony 900 Slate1APOC Polyset AH-160 · HFC / HFO1119

Single paddy: 45 g

NOA 24-1008.12 · p. 7 · Table 6 (opens in a new tab)

Westlake Saxony 900 Slate2DAP StormBond 2109

Two paddies: 8 g each

NOA 24-1008.12 · p. 6 · Table 5 (opens in a new tab)

Westlake Saxony 900 Slate3DuPont TILE BOND65

Independent · two paddies: 25 g each

NOA 24-1008.12 · p. 6 · Table 5 (opens in a new tab)

The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation.

Westlake Saxony 900 Slate4DAP StormBond · one component59

Two paddies: 8 g each

NOA 24-1008.12 · p. 6 · Table 5 (opens in a new tab)

Below component flat/low minima 10.2 g at head and 18.3 g on side. The tile row names StormBond without a formulation designation; its amounts also fall below the separate Low GWP component details. DAP and the roof designer must reconcile the applicable formulation and installation requirements before project use. These are published values, not jobsite dispensing instructions.

Westlake Saxony 900 Slate5APOC Polyset RTA-1 · HFO41

Two paddies: 12 g underlayment + 10 g headlap

NOA 24-1008.12 · p. 6 · Table 5 (opens in a new tab)

Mass and contact minimums align with the flat HFO drawing; tile row says 1 x 10 inch headlap while component drawing says 1 x 8 inch bead and minimum 10 in2 contact. Component Table 1 versus drawing conflict still needs resolution.

Crown Windsor Slate1DAP StormBond 2122

Two paddies: 8 g each

NOA 25-0127.10 · p. 7 · Table 5 (opens in a new tab)

Crown Windsor Slate2APOC Polyset AH-160 · HFC / HFO1119

Single paddy: 45 g

NOA 25-0127.10 · p. 8 · Table 6 (opens in a new tab)

Crown Windsor Slate3DAP StormBond · one component98

Two paddies: 18 g underlayment + 10 g headlap

NOA 25-0127.10 · p. 7 · Table 5 (opens in a new tab)

Close to but below component flat/low minima 18.3 g on side and 10.2 g at head. Do not round. The tile row names StormBond without a formulation designation; its amounts also fall below the separate Low GWP component details. DAP and the roof designer must reconcile the applicable formulation and installation requirements before project use. These are published values, not jobsite dispensing instructions.

Crown Windsor Slate4DuPont TILE BOND65

Independent · two paddies: 25 g each

NOA 25-0127.10 · p. 7 · Table 5 (opens in a new tab)

The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation.

Crown Windsor Slate5APOC Polyset RTA-1 · HFO38

Two paddies, 11 g each

NOA 25-0127.10 · p. 7 · Table 5 (opens in a new tab)

Tile row specifies 11 g each; component flat HFO drawing specifies 12 g underlayment and 10 g headlap. Contact is unspecified in tile table. Reconcile quantities and contact before installation.

Westlake Villa 9001APOC Polyset AH-160 · HFC / HFO187

Single paddy: 54 g

NOA 26-0602.02 · p. 6 · Table 6 (opens in a new tab)

Westlake Villa 9002APOC Polyset RTA-1 · HFO71

Two paddies: 12 g underlayment + 10 g headlap

NOA 26-0602.02 · p. 6 · Table 5 (opens in a new tab)

Tile row headlap contact is 8 in2; component medium HFO drawing requires at least 10 in2. Mass matches the drawing, but contact detail needs reconciliation.

Westlake Villa 9003DAP StormBond 270

Single paddy: 60 g

NOA 26-0602.02 · p. 6 · Table 6 (opens in a new tab)

Highest verified, unambiguous StormBond 2 foam-only entry. Table 5 also prints a 72 ft-lbf row at 8 g underlayment + 5 g headlap with the StormBond 2 name, but the duplicate product labeling is unresolved. That ambiguous entry is excluded from this comparison; it is not relabeled as one-component StormBond.

Westlake Villa 9004DuPont TILE BOND67

Independent · two paddies: 25 g each

NOA 26-0602.02 · p. 6 · Table 5 (opens in a new tab)

The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation.

Westlake Villa 900UnrankedDAP StormBond · one componentUnavailable

No verified, unambiguous entry in the reviewed tile approval

NOA 26-0602.02 · p. 6 · Table 5 (opens in a new tab)

The current Villa 900 approval lists StormBond in its product section, but both relevant Table 5 rows are labeled StormBond 2. The 72 ft-lbf row cannot be assigned to one-component StormBond without clarification.

Crown Tuscany1DAP StormBond 2108

Two paddies: 8 g each

NOA 25-0127.09 · p. 6 · Table 6 (opens in a new tab)

Crown Tuscany2APOC Polyset AH-160 · HFC / HFO187

Single paddy: 54 g

NOA 25-0127.09 · p. 6 · Table 7 (opens in a new tab)

Crown Tuscany3DAP StormBond · one component86

Two paddies: 8 g underlayment + 5 g headlap

NOA 25-0127.09 · p. 6 · Table 6 (opens in a new tab)

Below component low/medium minima 8.4 g flange and 5.1 g head. The tile row names StormBond without a formulation designation; its amounts also fall below the separate Low GWP component details. DAP and the roof designer must reconcile the applicable formulation and installation requirements before project use. These are published values, not jobsite dispensing instructions.

Crown Tuscany4DuPont TILE BOND67

Independent · two paddies: 25 g each

NOA 25-0127.09 · p. 6 · Table 6 (opens in a new tab)

The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation.

Crown Tuscany5APOC Polyset RTA-1 · HFO44.6

Two paddies: 12 g underlayment + 10 g headlap

NOA 25-0127.09 · p. 6 · Table 6 (opens in a new tab)

Tile row headlap contact is 8 in2; component medium HFO drawing requires at least 10 in2. Mass matches the drawing, but contact detail needs reconciliation.

Westlake Barcelona 9001DAP StormBond 282

Single paddy: 60 g

NOA 24-1008.13 · p. 7 · Table 6 (opens in a new tab)

Highest StormBond 2 foam-only value among the verified rows in this tile approval. The separate two-paddy 8 g-each entry is 66 ft-lbf; it is not the highest listed pattern.

Westlake Barcelona 9002APOC Polyset AH-160 · HFC / HFO167

Single paddy: 63 g

NOA 24-1008.13 · p. 7 · Table 6 (opens in a new tab)

Westlake Barcelona 9003DuPont TILE BOND58

Independent · two paddies: 12.5 g each

NOA 24-1008.13 · p. 6 · Table 5 (opens in a new tab)

The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation.

Westlake Barcelona 9004DAP StormBond · one component48

Two paddies: 8 g underlayment + 4 g headlap

NOA 24-1008.13 · p. 6 · Table 5 (opens in a new tab)

Underlayment amount below component high-profile 8.4 g flange minimum; head 4 g is above 3.9 g minimum. The tile row names StormBond without a formulation designation; its amounts also fall below the separate Low GWP component details. DAP and the roof designer must reconcile the applicable formulation and installation requirements before project use. These are published values, not jobsite dispensing instructions.

Westlake Barcelona 9005APOC Polyset RTA-1 · HFO44

Two paddies: 12 g underlayment + 12 g headlap

NOA 24-1008.13 · p. 6 · Table 5 (opens in a new tab)

Tile row headlap contact is 10 in2; component high HFO drawing requires at least 18 in2. Mass matches the drawing, but contact detail needs reconciliation.

Crown Sanibel1DAP StormBond 2101

Two paddies: 8 g each

NOA 24-1008.16 · p. 5 · Table 5 (opens in a new tab)

Crown Sanibel2APOC Polyset AH-160 · HFC / HFO167

Single paddy: 63 g

NOA 24-1008.16 · p. 6 · Table 6 (opens in a new tab)

Crown Sanibel3DAP StormBond · one component59

Two paddies: 8 g underlayment + 4 g headlap

NOA 24-1008.16 · p. 5 · Table 5 (opens in a new tab)

Underlayment amount below component high-profile 8.4 g flange minimum; head 4 g is above 3.9 g minimum. The tile row names StormBond without a formulation designation; its amounts also fall below the separate Low GWP component details. DAP and the roof designer must reconcile the applicable formulation and installation requirements before project use. These are published values, not jobsite dispensing instructions.

Crown Sanibel4DuPont TILE BOND58

Independent · two paddies: 12.5 g each

NOA 24-1008.16 · p. 5 · Table 5 (opens in a new tab)

The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation.

Crown Sanibel5APOC Polyset RTA-1 · HFO53.5

Two paddies: 22 g underlayment + 11 g headlap

NOA 24-1008.16 · p. 5 · Table 5 (opens in a new tab)

Tile row has 22 g underlayment and 11 g headlap; component high HFO drawing specifies 12 g each. Headlap mass is below that drawing; tile contact is unspecified. Needs reconciliation.

Verea Spanish S · Grade 11DAP StormBond 283

Two paddies: 9.7 g each

NOA 25-0206.03 · p. 5 · Table 6 (opens in a new tab)

Verea Spanish S · Grade 12DAP StormBond · one component81

Two paddies: 9.6 g each

NOA 25-0206.03 · p. 5 · Table 6 (opens in a new tab)

Each 9.6 g paddy exceeds the component clay-S mass minimums for the original detail (3.3 g head / 8.4 g underlayment side) and Low GWP detail (3.5 g / 9.3 g). The tile row does not identify a formulation or contact area, so exact product, placement and the complete assembly still require confirmation.

Verea Spanish S · Grade 13APOC Polyset AH-160 · HFC / HFO163

Single paddy: 34.6 g

NOA 25-0206.03 · p. 5 · Table 7 (opens in a new tab)

Verea Spanish S · Grade 14DuPont TILE BOND54

Independent · two paddies: 27.5 g each

NOA 25-0206.03 · p. 5 · Table 6 (opens in a new tab)

The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation.

Verea Spanish S · Grade 1UnrankedAPOC Polyset RTA-1 · HFOUnavailable

No entry in the reviewed tile approval

NOA 25-0206.03 · p. 5 · Tables 6–7 (opens in a new tab)

No approval or performance value for this pairing is inferred from another tile.

Verea True Barrel · Grade 11ICP Polyset AH-160 · legacy HFC118.31

34.6 g per pan; 17.3 g on each side of cap

NOA 22-1202.03 · p. 5 · Table 6 (opens in a new tab)

Legacy Polyset AH-160 entry; not an HFO1 or HFO2 result. Table 6, footnote 3.

Verea True Barrel · Grade 12DuPont TILE BOND89.8

12.5 g per pan; 12.5 g on each side of cap

NOA 22-1202.03 · p. 5 · Table 6 (opens in a new tab)

The tile table names TILE BOND without a separate HFO designation. Confirm the supplied formulation. Table 6, footnote 4.

Verea True Barrel · Grade 1UnrankedAPOC Polyset RTA-1 · HFOUnavailable

No entry in the reviewed tile approval

NOA 22-1202.03 · p. 5 · Table 6 (opens in a new tab)

No approval or performance value for this pairing is inferred from another tile.

Verea True Barrel · Grade 1UnrankedDAP StormBond · one componentUnavailable

No verified, unambiguous entry in the reviewed tile approval

NOA 22-1202.03 · p. 5 · Table 6 (opens in a new tab)

No StormBond entry was found anywhere in the reviewed Verea Barrel tile approval. The component approval alone does not supply a tile-specific value.

Verea True Barrel · Grade 1UnrankedDAP StormBond 2Unavailable

No entry in the reviewed tile approval

NOA 22-1202.03 · p. 5 · Table 6 (opens in a new tab)

No approval or performance value for this pairing is inferred from another tile.

Take one question to your roofer

“Can you show me the attachment detail for my exact tile, and explain how it meets the requirements for my roof?”

The five foams on the list

Each can rank differently when you change the tile. These summaries explain the differences; use the chart above for the numbered order on your profile.

APOC logo

Two components

APOC Polyset AH-160

Leads the reviewed rankings for Saxony 900 Slate, Villa 900 and Verea True Barrel.

The winning flat and medium-profile entries belong to HFC/HFO1; the True Barrel entry is legacy HFC. An AH-160 package marked HFO does not establish that every formulation has those same values.

DAP logo

Two components

DAP StormBond 2

Leads the reviewed rankings for Windsor Slate, Tuscany, Barcelona 900, Sanibel and Verea Spanish S.

Its strongest documented pattern changes with the tile. Barcelona’s 82 ft-lbf entry uses a single 60 g paddy; its two-paddy entry is 66 ft-lbf. The name alone is not the attachment specification.

DuPont logo

One component

DuPont TILE BOND

Has a verified entry for all eight tile profiles in this comparison, including the separate cap-and-pan True Barrel system.

Independent and interdependent patterns carry loads differently. For Saxony, the independent entry is 65 ft-lbf; the interdependent entry is 63. The higher number uses a different amount and arrangement of foam.

DAP logo

One component

DAP StormBond

The fifth product is the one-component StormBond. It is separate from StormBond 2 and has its own approval.

Published entries include 98 ft-lbf for Windsor Slate and 81 for Verea Spanish S. The five concrete-tile entries need reconciliation with current component application minimums. A generic tile-table name also does not establish a Low GWP substitution.

APOC logo

One component

APOC Polyset RTA-1

Its place changes by profile: the reviewed Villa 900 entry is 71 ft-lbf, while the Saxony 900 Slate entry is 41.

RTA-1 has no verified entry in either Verea approval used here. Some tile-table details differ from its current component approval, which also contains table-versus-drawing differences. Those details need manufacturer and designer confirmation.

How we chose the strength rankings

We reviewed attachment tables for eight exact Westlake, Crown and Verea tiles. For each product-and-tile pairing, we selected the highest verified, unambiguous foam-only entry in those tables. We kept the named formulation, foam pattern, source page and manufacturing location with the value.

Same tile, ranked from highest to lowest

Changing the tile can change the order. We do not average unlike tiles into one brand score or treat an unavailable entry as zero.

A consistent graph scale

Every tile uses the same scale starting at zero. A bar does not become more impressive just because you choose a different profile.

Foam-only entries

We exclude mechanical-only, mortar and hybrid attachment details from this ranking. Those are different systems.

Exact formulas and patterns

One- and two-component products, HFC, HFO1, HFO2 and Low GWP labels cannot be swapped without checking their approvals.

Some published details need clarification before project use

Certain RTA-1 tile-table details differ from its current component approval, which also has table-versus-drawing differences. The five ranked concrete-tile entries for one-component StormBond use amounts below current component minimums. We show the published values with notes; the manufacturer and roof designer must reconcile the applicable details before they are used on a roof.

The Villa 900 table also prints an ambiguous second StormBond 2 row at 72 ft-lbf. We exclude that row, use the clear 70 ft-lbf single-paddy entry, and leave one-component StormBond unranked for Villa. We do not guess which product the ambiguous row was intended to identify.

An NOA is a Miami-Dade Notice of Acceptance. The adhesive’s component NOA describes the foam and its requirements; the tile NOA supplies the attachment values for that tile. The roof design must connect both to the actual demands on your home. Read our guide to checking roofing approvals for the documents to ask for.

A strong attachment is one part of a dependable roof

The highest bar does not automatically make a product the best choice for your house. Your roof’s shape, height, exposure, edges and corners affect the attachment demands. Ask for the exact tile profile, foam formulation and approved detail in your estimate.

Holding the tile

The attachment detail needs to meet the roof’s wind requirements. Correct placement and installation matter alongside the published number.

Keeping water out

Underlayment and flashing protect the home beneath and around the tile. Foam cannot make up for damaged decking or incomplete waterproofing.

Getting help later

Ask who handles loose tiles or leaks, what the written workmanship coverage includes and whether matching replacement tiles are available.

Using Polystick TU MAX? Confirm the exact foam formulation and complete underlayment assembly together. A compatibility listing is useful, but it is not a wind rating for the whole roof.

Still choosing a profile? Explore our tile color and profile samples and tile roofing service guide, then compare attachment options for the tile you like.

Frequently asked questions

Which tile foam adhesive is the strongest?

There is no single winner for every tile. In the verified foam-only details shown here, AH-160 leads for Westlake Saxony 900 Slate at 119 ft-lbf, while StormBond 2 leads for Crown Windsor Slate at 122. Choose your exact tile in the chart, then have the listed formulation and attachment detail checked against your roof’s requirements.

Do these numbers tell me the wind speed my roof can handle?

No. Mf in ft-lbf is a moment measuring resistance to a tile lifting and rotating in a specific attachment arrangement. It is not a miles-per-hour rating, a direct foam-to-underlayment pull-off test or a rating for the whole roof. The roof designer must check the applicable wind demands, including edges and corners.

Why can one foam have more than one strength value?

The tile shape, foam formulation, amount, contact area and placement can change the result. For Barcelona 900, StormBond 2 has a 66 ft-lbf two-paddy entry and an 82 ft-lbf single-paddy entry in the cited NOA. These are separate approved-detail records, not permission to change the foam amount on the roof.

Are StormBond and StormBond 2 the same product?

No. StormBond is one component, while StormBond 2 uses two components mixed during application. They have separate component approvals. The estimate should identify the exact product and formulation, including any Low GWP designation.

Does a missing chart entry mean the adhesive is weak?

No. It means we do not have a verified, unambiguous value for that product and tile in the approvals reviewed. We leave it unranked rather than substitute another tile’s number or plot it as zero.

Can any of these foams go over Polystick TU MAX?

Polyglass NOA 25-0121.12 names these product families in its compatibility information, but formulation labels matter. For example, it expressly names AH-160 HFC; that does not separately establish HFO1 or HFO2. Have the roofer confirm the exact adhesive, underlayment assembly and tile attachment detail together.

What should I ask for in my tile roof estimate?

Ask for the tile profile, adhesive product and formulation, approved attachment detail, underlayment and flashing scope, wood-repair allowance, permits and written workmanship coverage. Foam holds the tile; the waterproofing beneath and around it has a separate job. Both belong in the estimate.

Sources checked October 24, 2026

Product approvals are revised and renewed. Confirm the current document for the exact product, plant and roof system when your permit is prepared. This guide is general information for homeowners, not an engineering or permit determination for a specific roof.